NSN 5915-01-236-0569 RF10420, 77C721111P001, 01-236-0569
Product Details | RADIO FREQUENCY INTERFERENCE FILTER
5915-01-236-0569 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.
Part Alternates: RF10420, 77C721111P001, 5915-01-236-0569, 01-236-0569, 5915012360569, 012360569
Electrical and Electronic Equipment Components | Filters and Networks
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 10 JUL 1986 | 01-236-0569 | 00765 ( FILTER, RADIO FREQUENCY INTERFERENCE ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5915-01-236-0569
Technical Data | NSN 5915-01-236-0569
| Characteristic | Specifications |
|---|---|
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE 50.0 OHMS 5TH RADIO INTERFERENCE |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE 50.0 OHMS 5TH RADIO INTERFERENCE |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 208.0 VOLTS AC 1ST RADIO INTERFERENCE 208.0 VOLTS AC 2ND RADIO INTERFERENCE 208.0 VOLTS AC 3RD RADIO INTERFERENCE 120.0 VOLTS AC 4TH RADIO INTERFERENCE 120.0 VOLTS AC 5TH RADIO INTERFERENCE |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 60.0 1ST RADIO INTERFERENCE 60.0 2ND RADIO INTERFERENCE 60.0 3RD RADIO INTERFERENCE 60.0 4TH RADIO INTERFERENCE 60.0 5TH RADIO INTERFERENCE |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 1ST RADIO INTERFERENCE 10.0 2ND RADIO INTERFERENCE 10.0 3RD RADIO INTERFERENCE 5.0 4TH RADIO INTERFERENCE 5.0 5TH RADIO INTERFERENCE |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 1ST RADIO INTERFERENCE 2.5 VOLTS AC 2ND RADIO INTERFERENCE 2.5 VOLTS AC 3RD RADIO INTERFERENCE 2.5 VOLTS AC 4TH RADIO INTERFERENCE 2.5 VOLTS AC 5TH RADIO INTERFERENCE |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 5 THREADED STUD INPUT 5 THREADED STUD OUTPUT |
| STYLE DESIGNATOR | 27 RECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES |
| OVERALL LENGTH | 9.000 INCHES NOMINAL |
| OVERALL HEIGHT | 11.620 INCHES NOMINAL |
| BODY LENGTH | 7.000 INCHES NOMINAL |
| BODY HEIGHT | 11.000 INCHES NOMINAL |
| BODY WIDTH | 1.870 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 5 THREADED BUSHING 4 THREADED HOLE |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNEF |
| NOMINAL THREAD SIZE | 0.750 INCHES |
| III AVERAGE POWER RATING PER FUNCTION | 3.6 KILOWATTS 1ST RADIO INTERFERENCE 3.6 KILOWATTS 2ND RADIO INTERFERENCE |
Restrictions/Controls & Freight Information | NSN 5915-01-236-0569
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-01-236-0569
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |