Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-01-244-6629 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: 4470309, 447-0309, 4470309003, 447-0309-003, 5915-01-244-6629, 01-244-6629, 5915012446629, 012446629

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 17 NOV 1986 01-244-6629

Drawings & Photos | NSN 5915-01-244-6629


Demand History | NSN 5915-01-244-6629

Part Number Request Date QTY Origin
447-0309-003 2019-04-94 5 DIBBS
5915-01-244-6629 2018-06-156 9 DIBBS
5915-01-244-6629 2014-12-346 6 DIBBS
5915-01-244-6629 2014-07-195 6 DIBBS

Cross Reference | NSN 5915-01-244-6629

Part Number Cage Code Manufacturer
447-0309 94756 BOEING COMPANY, THE DBA BOEING
447-0309-003 94756 BOEING COMPANY, THE DBA BOEING

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-244-6629

Technical Data | NSN 5915-01-244-6629

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC 1ST RADIO INTERFERENCE 115.0 VOLTS AC 2ND RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 1ST RADIO INTERFERENCE 60.0 2ND RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS 8.0 1ST RADIO INTERFERENCE 8.0 2ND RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION 1.3 VOLTS AC 1ST RADIO INTERFERENCE 1.3 VOLTS DC 2ND RADIO INTERFERENCE
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 2 THREADED STUD INPUT 2 THREADED STUD OUTPUT 1 THREADED STUD GROUND
STYLE DESIGNATOR 27 RECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES
OVERALL LENGTH 5.330 INCHES MINIMUM AND 5.420 INCHES MAXIMUM
OVERALL HEIGHT 2.220 INCHES MINIMUM AND 2.280 INCHES MAXIMUM
BODY LENGTH 4.470 INCHES MINIMUM AND 4.530 INCHES MAXIMUM
BODY HEIGHT 1.470 INCHES MINIMUM AND 1.530 INCHES MAXIMUM
BODY WIDTH 2.350 INCHES MINIMUM AND 2.410 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 3.985 INCHES MINIMUM AND 4.015 INCHES MAXIMUM
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE 0.164 INCHES
FEATURES PROVIDED MOISTURE RESISTANT AND SHOCK RESISTANT
SPECIAL FEATURES TWO UNFILTERED FUNCTIONS
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
III MAXIMUM TEMP RISE 25.0 DEG CELSIUS
III UNPACKAGED UNIT WEIGHT 2.000 POUNDS
III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE 500.0 VOLTS AT SEA LEVEL
III VIBRATION RESISTANCE RANGE IN HERTZ 10.0 TO 2000.0
III OPERATING TEMP RANGE 0.0 TO 75.0 DEG CELSIUS
III BODY MATERIAL METAL
MANUFACTURERS CODE 94756
MFR SOURCE CONTROLLING REFERENCE 447-0309

Restrictions/Controls & Freight Information | NSN 5915-01-244-6629

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-01-244-6629

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative