5915-01-257-3478 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: NN070840, NN-0708-40, RF12170B, FC2497, FS2573478, FS2573-478, 3427335061, 34-2733506-1, 5915-01-257-3478, 01-257-3478, 5915012573478, 012573478

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 17 JUN 1987 01-257-3478

Drawings & Photos | NSN 5915-01-257-3478


Demand History | NSN 5915-01-257-3478

Part Number Request Date QTY Origin
34-2733506-1 2023-01-24 9 DIBBS
FC2497 2023-01-24 9 DIBBS
FS2573-478 2023-01-24 9 DIBBS
NN-0708-40 2023-01-24 9 DIBBS
RF12170B 2023-01-24 9 DIBBS
34-2733506-1 2021-09-272 25 DIBBS
FC2497 2021-09-272 25 DIBBS
FS2573-478 2021-09-272 25 DIBBS
NN-0708-40 2021-09-272 25 DIBBS
RF12170B 2021-09-272 25 DIBBS
34-2733506-1 2021-03-81 16 DIBBS
FC2497 2021-03-81 16 DIBBS
FS2573-478 2021-03-81 16 DIBBS
NN-0708-40 2021-03-81 16 DIBBS
RF12170B 2021-03-81 16 DIBBS
5915-01-257-3478 2011-08-215 75 DIBBS
5915-01-257-3478 2011-08-213 32 DIBBS
5915-01-257-3478 2011-01-07 33 DIBBS
5915-01-257-3478 2010-08-215 22 DIBBS
5915-01-257-3478 2010-07-183 12 DIBBS
5915-01-257-3478 2010-03-63 17 DIBBS
5915-01-257-3478 2009-08-233 10 DIBBS
5915-01-257-3478 2009-07-212 4 DIBBS

Cross Reference | NSN 5915-01-257-3478

Part Number Cage Code Manufacturer
34-2733506-1 67032 GENERAL DYNAMICS C4 SYSTEMS, INC.
FC2497 56528 FIL-COIL (FC) INC.
FS2573-478 56662 FREQUENCY SELECTIVE NETWORKS INC
NN-0708-40 66239 JMK, INC.
RF12170B 13619 EMS DEVELOPMENT CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-257-3478

Technical Data | NSN 5915-01-257-3478

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS BLANK
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 125.0 VOLTS AC BLANK
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 BLANK
OPERATING CURRENT RATING PER FUNCTION IN AMPS 40.0 BLANK
MAXIMUM VOLTAGE DROP PER FUNCTION 1.25 VOLTS AC BLANK
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 THREADED STUD INPUT 1 THREADED STUD OUTPUT
STYLE DESIGNATOR 5 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 13.125 INCHES NOMINAL
BODY LENGTH 12.000 INCHES NOMINAL
BODY HEIGHT 3.000 INCHES NOMINAL
BODY WIDTH 3.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED STUD 4 SLOT
MOUNTING SLOT WIDTH 0.300 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 2.000 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE 0.375 INCHES
FEATURES PROVIDED NUT AND WASHER
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE BLANK
III MAXIMUM TEMP RISE 25.0 DEG CELSIUS
III FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ 0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
III FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS 38.0 AND 80.0 AND 80.0 AND 80.0 AND 80.0 AND 80.0
III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE 800.0 VOLTS AT SEA LEVEL
III VIBRATION RESISTANCE RANGE IN HERTZ 10.0 TO 500.0
III OPERATING TEMP RANGE -55.0 TO 85.0 DEG CELSIUS
III BODY MATERIAL METAL
III END ITEM IDENTIFICATION 5805-01-245-9058 SMALL EXTENSION

Restrictions/Controls & Freight Information | NSN 5915-01-257-3478

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-01-257-3478

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group00DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityZThis is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item.
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each