Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-01-260-1404 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: 704AS7879, 8978791, 897879-1, 5915-01-260-1404, 01-260-1404, 5915012601404, 012601404

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 26 JUL 1987 01-260-1404

Drawings & Photos | NSN 5915-01-260-1404


Cross Reference | NSN 5915-01-260-1404

Part Number Cage Code Manufacturer
704AS7879 00779 TYCO ELECTRONICS CORPORATION
704AS7879 30003 NAVAL AIR SYSTEMS COMMAND
704AS7879 71468 ITT CORPORATION DBA I T T CANNON
897879-1 96214 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-260-1404

Technical Data | NSN 5915-01-260-1404

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE 50.0 OHMS 5TH RADIO INTERFERENCE 50.0 OHMS 6TH RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE 50.0 OHMS 5TH RADIO INTERFERENCE 50.0 OHMS 6TH RADIO INTERFERENCE
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 125.0 VOLTS DC 1ST RADIO INTERFERENCE 125.0 VOLTS DC 2ND RADIO INTERFERENCE 125.0 VOLTS DC 3RD RADIO INTERFERENCE 125.0 VOLTS DC 4TH RADIO INTERFERENCE 125.0 VOLTS DC 5TH RADIO INTERFERENCE 125.0 VOLTS DC 6TH RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS 6.0 1ST RADIO INTERFERENCE 6.0 2ND RADIO INTERFERENCE 6.0 3RD RADIO INTERFERENCE 6.0 4TH RADIO INTERFERENCE 6.0 5TH RADIO INTERFERENCE 6.0 6TH RADIO INTERFERENCE
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT 45 FRICTION W/GROUNDING STRAP AND PIN OUTPUT
STYLE DESIGNATOR 37 ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACE
OVERALL LENGTH 0.860 INCHES NOMINAL
BODY LENGTH 0.708 INCHES NOMINAL
BODY OUTSIDE DIAMETER 0.040 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 1 TERMINAL
SPECIAL FEATURES 45 FILTERED CONTACTS
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE
III INPUT TERMINAL MANUFACTURER CODE 71468
III INPUT TERMINAL IDENTIFICATION 704AS7879
III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE 375.0 VOLTS AT SEA LEVEL
III PRECIOUS MATERIAL GOLD
III PRECIOUS MATERIAL AND CONTACT SURFACES GOLD

Restrictions/Controls & Freight Information | NSN 5915-01-260-1404

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:GItem contains gold
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-01-260-1404

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each