NSN 5915-01-274-9169 F100BW103S, 5122609-002-105, 01-274-9169
Product Details | RADIO FREQUENCY INTERFERENCE FILTER
5915-01-274-9169 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.
Part Alternates: F100BW103S, 5122609-002-105, 5915-01-274-9169, 01-274-9169, 5122609002105, 5915012749169, 012749169
Electrical and Electronic Equipment Components | Filters and Networks
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 16 MAR 1988 | 01-274-9169 | 00765 ( FILTER, RADIO FREQUENCY INTERFERENCE ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5915-01-274-9169
Technical Data | NSN 5915-01-274-9169
| Characteristic | Specifications |
|---|---|
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 100.0 VOLTS DC BLANK |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 BLANK |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS DC BLANK |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 THREADED STUD INPUT 1 THREADED STUD OUTPUT |
| STYLE DESIGNATOR | 9 ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| OVERALL LENGTH | 5.141 INCHES MAXIMUM |
| BODY LENGTH | 3.372 INCHES MAXIMUM |
| BODY OUTSIDE DIAMETER | 1.515 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNEF |
| NOMINAL THREAD SIZE | 0.750 INCHES |
| III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
| III FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.15 AND 1.0 AND 1000.0 |
| III FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 60.0 AND 80.0 AND 80.0 |
| III OPERATING TEMP RANGE | -25.0 TO 125.0 DEG CELSIUS |
Restrictions/Controls & Freight Information | NSN 5915-01-274-9169
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TH | Defense Supply Center Columbus Columbus, OH 43215 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |