NSN 5915-01-336-7668 50041009, 5004-1009, 8415741
Product Details | RADIO FREQUENCY INTERFERENCE FILTER
5915-01-336-7668 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.
Part Alternates: 50041009, 5004-1009, 8415741, 841574-1, 99085502XA, 9908-550-2XA, TBD, 5915-01-336-7668, 01-336-7668, 5915013367668, 013367668
Electrical and Electronic Equipment Components | Filters and Networks
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 03 APR 1991 | 01-336-7668 | 00765 ( FILTER, RADIO FREQUENCY INTERFERENCE ) |
Demand History | NSN 5915-01-336-7668
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| TBD | 2025-11-310 | 1 | US |
| TBD | 2025-11-310 | 1 | US |
| TBD | 2025-04-101 | 6 | US |
| TBD | 2020-07-184 | 10 | US |
| TBD | 2018-07-190 | 2 | United States |
| 5915-01-336-7668 | 2014-04-119 | 2 | US |
| 5915-01-336-7668 | 2014-04-91 | 2 | US |
Cross Reference | NSN 5915-01-336-7668
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 5004-1009 | 13050 | SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON |
| 841574-1 | 06481 | NORTHROP GRUMMAN SYSTEMS CORPORATION |
| 841574-1 | 13973 | LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISION |
| 9908-550-2XA | 79474 | GREATBATCH SIERRA INC DBA USE CAGE CODE 58421 FOR |
| TBD | 05245 | CORCOM INC DIV CIS/CORCOM |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5915-01-336-7668
Technical Data | NSN 5915-01-336-7668
| Characteristic | Specifications |
|---|---|
| SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE |
| LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE |
| OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 150.0 VOLTS AC 1ST RADIO INTERFERENCE 150.0 VOLTS AC 2ND RADIO INTERFERENCE |
| POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 460.0 1ST RADIO INTERFERENCE 460.0 2ND RADIO INTERFERENCE |
| OPERATING CURRENT RATING PER FUNCTION IN AMPS | 6.0 1ST RADIO INTERFERENCE 6.0 2ND RADIO INTERFERENCE |
| MAXIMUM VOLTAGE DROP PER FUNCTION | 3.0 VOLTS AC 1ST RADIO INTERFERENCE 3.0 VOLTS AC 2ND RADIO INTERFERENCE |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, PLUG INPUT 2 TAB, SOLDER LUG OUTPUT 1 TAB, SOLDER LUG GROUND |
| STYLE DESIGNATOR | 5 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| OVERALL LENGTH | 6.312 INCHES NOMINAL |
| BODY LENGTH | 6.000 INCHES NOMINAL |
| BODY HEIGHT | 3.000 INCHES NOMINAL |
| BODY WIDTH | 1.250 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.500 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.625 INCHES NOMINAL |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
| NOMINAL THREAD SIZE | 0.164 INCHES |
| FEATURES PROVIDED | FUNGUS RESISTANT AND SHOCK RESISTANT |
| SPECIAL FEATURES | TWO FILTERED FUNCTIONS |
| III AVERAGE POWER RATING PER FUNCTION | 1.5 WATTS 1ST RADIO INTERFERENCE 1.5 WATTS 2ND RADIO INTERFERENCE |
| III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| III MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
| III FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0 |
| III FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 20.0 AND 75.0 AND 90.0 AND |
Restrictions/Controls & Freight Information | NSN 5915-01-336-7668
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TH | Defense Supply Center Columbus Columbus, OH 43215 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-01-336-7668
| Category | Code | Description |
|---|---|---|
| Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
| Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
| Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
| Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DF | Department of the Air Force |
| Service Organization | F | U.S. Air Force |
| Reparability | N | Stock Fund (except Munitions) |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
| Combat Essentiality Code | 2 | Non-Critical Repair Part. Repair parts or major components whose failure in an end item will not render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency, and which do not fit the definition of Code 3 or 4 items. |
| Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
| Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
| Physical Category Code | 1 | Bin |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DM | U.S. Marine Corps |
| Service Organization | M | U.S. Marine Corps |
| Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |