Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-01-341-6886 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: G2812691, G281269-1, 5915-01-341-6886, 01-341-6886, 5915013416886, 013416886

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 05 JUL 1991 01-341-6886

Drawings & Photos | NSN 5915-01-341-6886


Demand History | NSN 5915-01-341-6886

Part Number Request Date QTY Origin
5915-01-341-6886 2010-07-210 1 DIBBS
5915-01-341-6886 2009-09-271 1 DIBBS

Cross Reference | NSN 5915-01-341-6886

Part Number Cage Code Manufacturer
G281269-1 3B150 RAYTHEON TECHNICAL SERVICES COMPANY LLC
G281269-1 49956 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-341-6886

Technical Data | NSN 5915-01-341-6886

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 440.0 VOLTS AC 1ST RADIO INTERFERENCE 440.0 VOLTS AC 2ND RADIO INTERFERENCE 440.0 VOLTS AC 3RD RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 60.0 1ST RADIO INTERFERENCE 60.0 2ND RADIO INTERFERENCE 60.0 3RD RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS 25.0 1ST RADIO INTERFERENCE 25.0 2ND RADIO INTERFERENCE 25.0 3RD RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION 1.2 VOLTS AC 1ST RADIO INTERFERENCE 1.2 VOLTS AC 2ND RADIO INTERFERENCE 1.2 VOLTS AC 3RD RADIO INTERFERENCE
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT 3 THREADED STUD OUTPUT 1 PIN GROUND
STYLE DESIGNATOR 23 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 17.250 INCHES NOMINAL
OVERALL HEIGHT 8.406 INCHES NOMINAL
BODY LENGTH 16.000 INCHES NOMINAL
BODY HEIGHT 6.000 INCHES MAXIMUM
BODY WIDTH 5.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 14 UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER 0.199 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 16.625 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 5.626 INCHES NOMINAL
FEATURES PROVIDED SHOCK RESISTANT
SPECIAL FEATURES THREE FILTERED FUNCTIONS
III AVERAGE POWER RATING PER FUNCTION 60.0 WATTS 1ST RADIO INTERFERENCE 60.0 WATTS 2ND RADIO INTERFERENCE 60.0 WATTS 3RD RADIO INTERFERENCE
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
III MAXIMUM TEMP RISE 40.0 DEG CELSIUS
III AVERAGE LIFE RATING IN HOURS 10000.0
III INPUT TERMINAL MANUFACTURER CODE 96906

Restrictions/Controls & Freight Information | NSN 5915-01-341-6886

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:GItem contains gold
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-01-341-6886

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each