Product Details | CARTRIDGE FUSE

5920-00-184-0838 A fuse in which the element is inclosed in a cylindrical body. The element may be renewable. The terminals may be of varying types. It may contain a visual indication that the fusible element is severed, and may also provide an audible alarm through auxiliary circuitry. For noncylindrical items, see FUSE, INCLOSED LINK.

Part Alternates: MDL316, MDL3-16, 65K892098, 1263A316, 1263A3-16, 18507446, 185074-46, 28053 3-16, 28053316, 28053-3-16, 313187, 313-187, 5920-00-184-0838, 00-184-0838, 5920001840838, 001840838

Electrical and Electronic Equipment Components | Fuses, Arrestors, Absorbers, and Protectors

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1961 00-184-0838

Drawings & Photos | NSN 5920-00-184-0838


Cross Reference | NSN 5920-00-184-0838

Part Number Cage Code Manufacturer
1263A3-16 75915 LITTELFUSE, INC.
185074-46 37695 RAYTHEON COMPANY DBA RAYTHEON
28053 3-16 80064 NAVAL SHIP SYSTEMS COMMAND
28053-3-16 80064 NAVAL SHIP SYSTEMS COMMAND
313-187 75915 LITTELFUSE, INC.
65K892098 1VPW8 GENERAL DYNAMICS C4 SYSTEMS, INC.
65K892098 94990 MOTOROLA INC. DBA INTEGRATED INFORMATION SYSTEMS
MDL3-16 71400 COOPER BUSSMANN INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5920-00-184-0838

Technical Data | NSN 5920-00-184-0838

Characteristic Specifications
BODY STYLE 2A TUBE TYPE
OVERALL LENGTH 1.250 INCHES NOMINAL
OVERALL DIAMETER 0.250 INCHES NOMINAL
CONTINUOUS CURRENT RATING IN AMPS 0.1875
MAXIMUM VOLTAGE RATING IN VOLTS 250.0 DC
CIRCUIT OVER-CURRENT INTERRUPTION TYPE TIME DELAY
CIRCUIT OVER-CURRENT INTERRUPTION DELAY TIME IN SECONDS 25.0 200 PCT OF CURRENT RATING AND 8.0 300 PCT OF CURRENT RATING AND 3.0 500 PCT OF CURRENT RATING
INTERRUPTION INDICATOR METHOD VISIBLE ELEMENT
SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS ANY ACCEPTABLE
TERMINAL SURFACE TREATMENT NICKEL
FEATURES PROVIDED NONRENEWABLE FUSIBLE ELEMENT
III CASE MATERIAL GLASS

Restrictions/Controls & Freight Information | NSN 5920-00-184-0838

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information