Product Details | CARTRIDGE FUSE

5920-01-181-5700 A fuse in which the element is inclosed in a cylindrical body. The element may be renewable. The terminals may be of varying types. It may contain a visual indication that the fusible element is severed, and may also provide an audible alarm through auxiliary circuitry. For noncylindrical items, see FUSE, INCLOSED LINK.

Part Alternates: 5920-01-181-5700, 01-181-5700, 5920011815700, 011815700

Electrical and Electronic Equipment Components | Fuses, Arrestors, Absorbers, and Protectors

Supply Group (FSG) NSN Assign. NIIN
59 01-181-5700

Drawings & Photos | NSN 5920-01-181-5700


Cross Reference | NSN 5920-01-181-5700

Part Number Cage Code Manufacturer
40107-304-007 14668 CALCOMP INC
462839 19139 EASTMAN KODAK COMPANY DBA KODAK
F09B250V7A 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
F09G7R00B 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
GFE7A250V 0VF14 ZZYZX PERIPHERALS INC.
MIL-PRF-15160/9 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MILF15160-09 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MS90085-63 96906 MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5920-01-181-5700

Technical Data | NSN 5920-01-181-5700

Characteristic Specifications
BODY STYLE 2A TUBE TYPE
OVERALL LENGTH 1.500 INCHES NOMINAL
OVERALL DIAMETER 0.406 INCHES NOMINAL
CONTINUOUS CURRENT RATING IN AMPS 7.000
MAXIMUM VOLTAGE RATING IN VOLTS 250.0 AC
CIRCUIT OVER-CURRENT INTERRUPTION TYPE TIME DELAY
CIRCUIT OVER-CURRENT INTERRUPTION DELAY TIME IN SECONDS 30.0 110 PCT OF CURRENT RATING
INTERRUPTION INDICATOR METHOD VISIBLE ELEMENT
SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS 200000.0
TERMINAL SURFACE TREATMENT NICKEL
FEATURES PROVIDED NONRENEWABLE FUSIBLE ELEMENT
III CASE MATERIAL FIBER
III TERMINAL MATERIAL COPPER ALLOY
III FRAGILITY FACTOR MODERATELY RUGGED

Restrictions/Controls & Freight Information | NSN 5920-01-181-5700

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information