Product Details | CARTRIDGE FUSE

5920-01-433-3711 A fuse in which the element is inclosed in a cylindrical body. The element may be renewable. The terminals may be of varying types. It may contain a visual indication that the fusible element is severed, and may also provide an audible alarm through auxiliary circuitry. For noncylindrical items, see FUSE, INCLOSED LINK.

Part Alternates: MIL-F 123419/7, MILF1234197, 23391065, 2339-1065, 269003, 5920-01-433-3711, 01-433-3711, 5920014333711, 014333711

Electrical and Electronic Equipment Components | Fuses, Arrestors, Absorbers, and Protectors

Supply Group (FSG) NSN Assign. NIIN
59 27 JUN 1996 01-433-3711

Drawings & Photos | NSN 5920-01-433-3711


Cross Reference | NSN 5920-01-433-3711

Part Number Cage Code Manufacturer
2339-1065 K0216 THALES OPTRONICS LIMITED
2339-1065 U1746 THALES OPTRONICS TAUNTON LTD
269003 75915 LITTELFUSE, INC.
269003 K8473 LITTELFUSE UK LTD
MIL-F 123419/7 K8473 LITTELFUSE UK LTD

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5920-01-433-3711

Technical Data | NSN 5920-01-433-3711

Characteristic Specifications
BODY STYLE 30A PLUG-IN TYPE
OVERALL LENGTH 0.460 INCHES NOMINAL
TERMINAL LENGTH 0.170 INCHES NOMINAL
BODY LENGTH 0.290 INCHES NOMINAL
OVERALL DIAMETER 0.235 INCHES NOMINAL
TERMINAL DIAMETER 0.025 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO DIAMETER 0.100 INCHES NOMINAL
CONTINUOUS CURRENT RATING IN AMPS 3.000
MAXIMUM VOLTAGE RATING IN VOLTS 125.0 AC
CIRCUIT OVER-CURRENT INTERRUPTION TYPE TIME DELAY
CIRCUIT OVER-CURRENT INTERRUPTION DELAY TIME IN SECONDS 5.0 200 PCT OF CURRENT RATING
INTERRUPTION INDICATOR METHOD OPAQUE BODY
SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS 10000.0
TERMINAL SURFACE TREATMENT GOLD PLATED
FEATURES PROVIDED NONRENEWABLE FUSIBLE ELEMENT
III PRECIOUS MATERIAL GOLD
III PRECIOUS MATERIAL AND LOCATION TERMINAL SURFACES GOLD

Restrictions/Controls & Freight Information | NSN 5920-01-433-3711

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:GItem contains gold
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information