NSN 5925-00-071-9844 AM0666MG625208VAC60C4, AM0666MG6-25-208VAC60C4, AM0666MG6SW50250VRC25208V60C4
Product Details | CIRCUIT BREAKER
5925-00-071-9844 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Part Alternates: AM0666MG625208VAC60C4, AM0666MG6-25-208VAC60C4, AM0666MG6SW50250VRC25208V60C4, AM0666MG6SW50-250VRC25-208V60C4, CB5461R, 5925-00-071-9844, 00-071-9844, 5925000719844, 000719844
Electrical and Electronic Equipment Components | Circuit Breakers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 25 JUL 1967 | 00-071-9844 | 00136 ( CIRCUIT BREAKER ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5925-00-071-9844
Technical Data | NSN 5925-00-071-9844
| Characteristic | Specifications |
|---|---|
| POLE QUANTITY | 4 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC FIRST LOCATION 25.0 AMPERES AC SECOND LOCATION 25.0 AMPERES AC THIRD LOCATION 25.0 AMPERES AC FOURTH LOCATION |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC FIRST LOCATION 208.0 AC SECOND LOCATION 208.0 AC THIRD LOCATION 208.0 AC FOURTH LOCATION |
| FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SECOND LOCATION 1000.0 AC THIRD LOCATION 1000.0 AC FOURTH LOCATION |
| CIRCUIT PROTECTION TYPE | OVERCURRENT SECOND LOCATION OVERCURRENT THIRD LOCATION OVERCURRENT FOURTH LOCATION |
| TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SECOND LOCATION MAGNETIC-HYDRAULIC THIRD LOCATION MAGNETIC-HYDRAULIC FOURTH LOCATION |
| INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP SECOND LOCATION RELAY TRIP THIRD LOCATION RELAY TRIP FOURTH LOCATION |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY SECOND LOCATION TIME DELAY THIRD LOCATION TIME DELAY FOURTH LOCATION |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 4.100 MINIMUM AT 200 PCT AND 14.000 MAXIMUM AT 200 PCT SECOND LOCATION 4.100 MINIMUM AT 200 PCT AND 14.000 MAXIMUM AT 200 PCT THIRD LOCATION 4.100 MINIMUM AT 200 PCT AND 14.000 MAXIMUM AT 200 PCT FOURTH LOCATION |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SECOND LOCATION 125.0 THIRD LOCATION 125.0 FOURTH LOCATION |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| BODY STYLE | 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| BODY LENGTH | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
| BODY WIDTH | 2.960 INCHES MINIMUM AND 3.040 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO | 2.052 INCHES MINIMUM AND |
Restrictions/Controls & Freight Information | NSN 5925-00-071-9844
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 658 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5925-00-071-9844
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |