Product Details | CIRCUIT BREAKER

5925-00-071-9844 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: AM0666MG625208VAC60C4, AM0666MG6-25-208VAC60C4, AM0666MG6SW50250VRC25208V60C4, AM0666MG6SW50-250VRC25-208V60C4, CB5461R, 5925-00-071-9844, 00-071-9844, 5925000719844, 000719844

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 25 JUL 1967 00-071-9844

Drawings & Photos | NSN 5925-00-071-9844


Cross Reference | NSN 5925-00-071-9844

Part Number Cage Code Manufacturer
AM0666MG6-25-208VAC60C4 74193 EATON CORP HEINEMANN PRODUCTS
AM0666MG6SW50-250VRC25-208V60C4 74193 EATON CORP HEINEMANN PRODUCTS
CB5461R 09017 EDO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-00-071-9844

Technical Data | NSN 5925-00-071-9844

Characteristic Specifications
POLE QUANTITY 4
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 50.0 AMPERES AC FIRST LOCATION 25.0 AMPERES AC SECOND LOCATION 25.0 AMPERES AC THIRD LOCATION 25.0 AMPERES AC FOURTH LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC FIRST LOCATION 208.0 AC SECOND LOCATION 208.0 AC THIRD LOCATION 208.0 AC FOURTH LOCATION
FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SECOND LOCATION 1000.0 AC THIRD LOCATION 1000.0 AC FOURTH LOCATION
CIRCUIT PROTECTION TYPE OVERCURRENT SECOND LOCATION OVERCURRENT THIRD LOCATION OVERCURRENT FOURTH LOCATION
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SECOND LOCATION MAGNETIC-HYDRAULIC THIRD LOCATION MAGNETIC-HYDRAULIC FOURTH LOCATION
INTERNAL TRIP RELEASE CONFIGURATION RELAY TRIP SECOND LOCATION RELAY TRIP THIRD LOCATION RELAY TRIP FOURTH LOCATION
TRIP RELEASE CHARACTERISTIC TIME DELAY SECOND LOCATION TIME DELAY THIRD LOCATION TIME DELAY FOURTH LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 4.100 MINIMUM AT 200 PCT AND 14.000 MAXIMUM AT 200 PCT SECOND LOCATION 4.100 MINIMUM AT 200 PCT AND 14.000 MAXIMUM AT 200 PCT THIRD LOCATION 4.100 MINIMUM AT 200 PCT AND 14.000 MAXIMUM AT 200 PCT FOURTH LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SECOND LOCATION 125.0 THIRD LOCATION 125.0 FOURTH LOCATION
RESET METHOD MANUAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY STYLE 8C MULTIPOLE-MULTIPLE ACTUATOR TYPE
BODY LENGTH 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
BODY WIDTH 2.960 INCHES MINIMUM AND 3.040 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO 2.052 INCHES MINIMUM AND

Restrictions/Controls & Freight Information | NSN 5925-00-071-9844

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5925-00-071-9844

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each