5925-00-421-2803 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: 5925-00-421-2803, 00-421-2803, 5925004212803, 004212803

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 00-421-2803

Drawings & Photos | NSN 5925-00-421-2803


Cross Reference | NSN 5925-00-421-2803

Part Number Cage Code Manufacturer
646-7025-001 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
77C703753PT8 03538 LOCKHEED MARTIN CORPORATION DIV MST
AP111-9H 81541 SENSATA TECHNOLOGIES MARYLAND, INC
M39019/05-218 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39019/05-83 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M39019/5-218 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-C-39019/5 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
SM333-2-60-2 74193 EATON CORP HEINEMANN PRODUCTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-00-421-2803

Technical Data | NSN 5925-00-421-2803

Characteristic Specifications
POLE QUANTITY 3
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 2.0 AMPERES AC ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 240.0 AC ALL LOCATIONS
FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 300.0 AC ALL LOCATIONS
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT AND 0.240 MAXIMUM AT 400 PCT ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 ALL LOCATIONS
ULTIMATE TRIP TIME PER POLE IN SECONDS 0.200 MINIMUM AND 7.000 MAXIMUM ALL LOCATIONS
RESET METHOD MANUAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY STYLE 1B MULTIPOLE-SINGLE ACTUATOR TYPE
BUSHING LENGTH 0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM
BODY LENGTH 1.552 INCHES MINIMUM AND 1.572 INCHES MAXIMUM
BODY WIDTH 1.844 INCHES MINIMUM AND 1.906 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.615 INCHES MINIMUM AND 0.635 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.690 INCHES MINIMUM AND 1.710 INCHES MAXIMUM
CASE MATERIAL METAL
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
THREAD SERIES DESIGNATOR UNEF
NOMINAL THREAD SIZE 0.375 INCHES
THREAD QUANTITY PER INCH 32
THREAD PITCH DIAMETERS 0.3503 TO 0.3537 INCHES
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE TWO
TERMINAL TYPE AND QUANTITY 6 WIRE HOOK
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND HERMETICALLY SEALED
TEST DATA DOCUMENT 81349-MIL-C-39019 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-C-39019/5 GOVERNMENT SPECIFICATION
III ARC QUENCHING METHOD MAGNETIC BLOWOUT
III STORAGE TYPE GENERAL PURPOSE WAREHOUSE