NSN 5925-00-421-2803 00-421-2803, 004212803
Product Details | CIRCUIT BREAKER
5925-00-421-2803 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Part Alternates: 5925-00-421-2803, 00-421-2803, 5925004212803, 004212803
Electrical and Electronic Equipment Components | Circuit Breakers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 00-421-2803 | 00136 ( CIRCUIT BREAKER ) |
Cross Reference | NSN 5925-00-421-2803
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 646-7025-001 | 13499 | ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS |
| 77C703753PT8 | 03538 | LOCKHEED MARTIN CORPORATION DIV MST |
| AP111-9H | 81541 | SENSATA TECHNOLOGIES MARYLAND, INC |
| M39019/05-218 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
| M39019/05-83 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
| M39019/5-218 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
| MIL-C-39019/5 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
| SM333-2-60-2 | 74193 | EATON CORP HEINEMANN PRODUCTS |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5925-00-421-2803
Technical Data | NSN 5925-00-421-2803
| Characteristic | Specifications |
|---|---|
| POLE QUANTITY | 3 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 2.0 AMPERES AC ALL LOCATIONS |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
| FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC ALL LOCATIONS |
| CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
| INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT AND 0.240 MAXIMUM AT 400 PCT ALL LOCATIONS |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
| ULTIMATE TRIP TIME PER POLE IN SECONDS | 0.200 MINIMUM AND 7.000 MAXIMUM ALL LOCATIONS |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| BODY STYLE | 1B MULTIPOLE-SINGLE ACTUATOR TYPE |
| BUSHING LENGTH | 0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM |
| BODY LENGTH | 1.552 INCHES MINIMUM AND 1.572 INCHES MAXIMUM |
| BODY WIDTH | 1.844 INCHES MINIMUM AND 1.906 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.615 INCHES MINIMUM AND 0.635 INCHES MAXIMUM |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.690 INCHES MINIMUM AND 1.710 INCHES MAXIMUM |
| CASE MATERIAL | METAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
| THREAD SERIES DESIGNATOR | UNEF |
| NOMINAL THREAD SIZE | 0.375 INCHES |
| THREAD QUANTITY PER INCH | 32 |
| THREAD PITCH DIAMETERS | 0.3503 TO 0.3537 INCHES |
| MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND HERMETICALLY SEALED |
| TEST DATA DOCUMENT | 81349-MIL-C-39019 SPECIFICATION |
| SPECIFICATION/STANDARD DATA | 81349-MIL-C-39019/5 GOVERNMENT SPECIFICATION |
| III ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
Restrictions/Controls & Freight Information | NSN 5925-00-421-2803
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||