Product Details | CIRCUIT BREAKER

5925-00-841-3559 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: AM12HKMG3125115VAC4, AM12HKMG3-1-25-115VAC4, S2711520P10, S271-1520P10, 2711520P10, 271-1520P10, 70613, 70-613, 7115304, 711530-4, 5925-00-841-3559, 00-841-3559, 5925008413559, 008413559

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1962 00-841-3559

Drawings & Photos | NSN 5925-00-841-3559


Cross Reference | NSN 5925-00-841-3559

Part Number Cage Code Manufacturer
271-1520P10 3B150 RAYTHEON TECHNICAL SERVICES COMPANY LLC
271-1520P10 49956 RAYTHEON COMPANY DBA RAYTHEON
70-613 74193 EATON CORP HEINEMANN PRODUCTS
711530-4 05869 RAYTHEON COMPANY DBA RAYTHEON
711530-4 82577 RAYTHEON COMPANY DBA RAYTHEON
AM12HKMG3-1-25-115VAC4 74193 EATON CORP HEINEMANN PRODUCTS
S271-1520P10 49956 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-00-841-3559

Technical Data | NSN 5925-00-841-3559

Characteristic Specifications
POLE QUANTITY 1
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 1.25 AMPERES AC SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 115.0 AC SINGLE LOCATION
FREQUENCY IN HERTZ 60.0 SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000.0 AC SINGLE LOCATION
CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.150 MINIMUM AT 200 PCT AND 1.500 MAXIMUM AT 200 PCT SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION
RESET METHOD MANUAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY STYLE 12A SINGLE POLE TYPE
BODY LENGTH 2.485 INCHES MINIMUM AND 2.515 INCHES MAXIMUM
BODY WIDTH 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.047 INCHES MINIMUM AND 2.077 INCHES MAXIMUM
BOSS HEIGHT 0.125 INCHES MINIMUM AND 0.155 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.595 INCHES MINIMUM AND 2.625 INCHES MAXIMUM
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE 0.138 INCHES
THREAD QUANTITY PER INCH 32
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE ONE
TERMINAL TYPE AND QUANTITY 2 THREADED STUD
AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS 5.0 AC AND 1.0 DC
SWITCH VOLTAGE RATING AND TYPE IN VOLTS 125.0 AC AND 50.0 DC
SWITCH TERMINAL TYPE TAB, SOLDER LUG

Restrictions/Controls & Freight Information | NSN 5925-00-841-3559

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5925-00-841-3559

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each