Product Details | CIRCUIT BREAKER

5925-00-984-0019 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: 5925-00-984-0019, 00-984-0019, 5925009840019, 009840019

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 00-984-0019

Drawings & Photos | NSN 5925-00-984-0019


Cross Reference | NSN 5925-00-984-0019

Part Number Cage Code Manufacturer
454-0009-045 94756 BOEING COMPANY, THE DBA BOEING
5SE01329-19 28638 NAVAL AIR WARFARE CENTER AIRCRAFT DIVISION CODE 1.3.1 BLDG 562-1
70-133-3MG6 74193 EATON CORP HEINEMANN PRODUCTS
711570-56REVE 05869 RAYTHEON COMPANY DBA RAYTHEON
711570-56REVE 82577 RAYTHEON COMPANY DBA RAYTHEON
AM1-A3-0.5-250AC-3 74193 EATON CORP HEINEMANN PRODUCTS
AM12-0-5-77 74193 EATON CORP HEINEMANN PRODUCTS
AM12MG3-500MA117VACCURVE4 74193 EATON CORP HEINEMANN PRODUCTS
AM12MG6-0-5-120VAC60C5 74193 EATON CORP HEINEMANN PRODUCTS
AM12MG6-0.5-120-60-5 74193 EATON CORP HEINEMANN PRODUCTS
APL1-124-8 81541 SENSATA TECHNOLOGIES MARYLAND, INC
CB5454 09017 EDO
M55629/1-011 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-C-55629/1 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-00-984-0019

Technical Data | NSN 5925-00-984-0019

Characteristic Specifications
POLE QUANTITY 1
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 500.0 MILLIAMPERES AC SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120.0 AC SINGLE LOCATION
FREQUENCY IN HERTZ 60.0 SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SINGLE LOCATION
CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.190 MINIMUM AT 200 PCT AND 1.500 MAXIMUM AT 200 PCT SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION
RESET METHOD MANUAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY STYLE 12A SINGLE POLE TYPE
BODY LENGTH 2.500 INCHES NOMINAL
BODY WIDTH 0.750 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.938 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.062 INCHES NOMINAL
BOSS HEIGHT 0.140 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.611 INCHES NOMINAL
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE 0.138 INCHES
THREAD QUANTITY PER INCH 32
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE ONE
TERMINAL TYPE AND QUANTITY 2 THREADED STUD
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF AND FUNGUS PROOF
III ARC QUENCHING METHOD MAGNETIC BLOWOUT
III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
III SPECIAL HANDLING FEATURE MAGNETIC
III FRAGILITY FACTOR MODERATELY RUGGED
MANUFACTURERS CODE 74193
DESIGN CONTROL REFERENCE AM12MG6-0.5-120-60-5

Restrictions/Controls & Freight Information | NSN 5925-00-984-0019

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information