Product Details | CIRCUIT BREAKER

5925-01-157-2113 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: 1611029200, 1611-029-200, 4963104, 5925-01-157-2113, 01-157-2113, 5925011572113, 011572113

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 30 JUN 1983 01-157-2113

Drawings & Photos | NSN 5925-01-157-2113


Cross Reference | NSN 5925-01-157-2113

Part Number Cage Code Manufacturer
1611-029-200 76374 EATON CORPORATION DBA FLUID POWER DIV USE CAGE CODE
4963104 72560 GENERAL MOTORS CORP DELCO PRODUCTS DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-01-157-2113

Technical Data | NSN 5925-01-157-2113

Characteristic Specifications
POLE QUANTITY 1
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 2.0 AMPERES AC SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SINGLE LOCATION
FREQUENCY IN HERTZ 60.0 SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC SINGLE LOCATION
CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
TRIP RELEASE METHOD THERMAL SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
TRIP RELEASE AMBIENT TEMP RATING 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 9.000 MINIMUM AT 200 PCT AND 45.000 MAXIMUM AT 200 PCT SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 145.0 SINGLE LOCATION
RESET METHOD MANUAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY STYLE 3A SINGLE POLE TYPE
BODY DIAMETER 0.437 INCHES NOMINAL
BUSHING LENGTH 0.375 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER 0.750 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.750 INCHES NOMINAL
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING
THREAD SERIES DESIGNATOR UNS
NOMINAL THREAD SIZE 0.438 INCHES
THREAD QUANTITY PER INCH 28
MANUAL ACTUATOR TYPE AND QUANTITY 1 PUSH BUTTON
ACTUATOR FUNCTION RESET
ACTUATOR POSITION DESIGNATION AT POLE ONE
TERMINAL TYPE AND QUANTITY 2 SCREW
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED SHOCKPROOF
III CUBIC MEASURE 44.000 CUBIC INCHES
III UNPACKAGED UNIT WEIGHT 8.000 OUNCES
III END ITEM IDENTIFICATION REGULATOR MODEL 3H18020A ONBOARD 82 FT COAST GUARD VESSELS
MANUFACTURERS CODE 76374
DESIGN CONTROL REFERENCE 1611-029-200

Restrictions/Controls & Freight Information | NSN 5925-01-157-2113

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information