Product Details | CIRCUIT BREAKER

5925-01-158-9056 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: APG6350253, APG-6-3-50-253, APG773325, APG-7-7332-5, 77C718000P5, 5925-01-158-9056, 01-158-9056, 5925011589056, 011589056

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 30 JUL 1983 01-158-9056

Drawings & Photos | NSN 5925-01-158-9056


Demand History | NSN 5925-01-158-9056

Part Number Request Date QTY Origin
77C718000P5 2019-05-148 21 DIBBS
APG-6-3-50-253 2019-05-148 21 DIBBS
APG-7-7332-5 2019-05-148 21 DIBBS
5925-01-158-9056 2019-05-134 45 US
5925-01-158-9056 2018-12-345 20 DIBBS
5925-01-158-9056 2018-09-267 15 DIBBS
5925-01-158-9056 2018-09-254 15 DIBBS
5925-01-158-9056 2013-10-287 16 DIBBS
5925-01-158-9056 2012-03-68 3 DIBBS
5925-01-158-9056 2006-06-157 3 DIBBS

Cross Reference | NSN 5925-01-158-9056

Part Number Cage Code Manufacturer
77C718000P5 03538 LOCKHEED MARTIN CORPORATION DIV MST
APG-6-3-50-253 81541 SENSATA TECHNOLOGIES MARYLAND, INC
APG-7-7332-5 81541 SENSATA TECHNOLOGIES MARYLAND, INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-01-158-9056

Technical Data | NSN 5925-01-158-9056

Characteristic Specifications
POLE QUANTITY 1
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 25.0 AMPERES DC SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 65.0 DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000.0 DC SINGLE LOCATION
CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SINGLE LOCATION
INTERNAL TRIP RELEASE CONFIGURATION SHUNT TRIP SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC INSTANTANEOUS SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 SINGLE LOCATION
RESET METHOD MANUAL
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY STYLE 12A SINGLE POLE TYPE
BODY LENGTH 2.000 INCHES NOMINAL
BODY WIDTH 0.750 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.530 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.660 INCHES NOMINAL
BOSS HEIGHT 0.130 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.000 INCHES MAXIMUM
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE 0.138 INCHES
THREAD QUANTITY PER INCH 32
THREAD PITCH DIAMETERS 0.1177 TO 0.1214 INCHES
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE ONE
TERMINAL TYPE AND QUANTITY 3 TAB W/SCREW
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT
III ARC QUENCHING METHOD MAGNETIC BLOWOUT
III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
III UNPACKAGED UNIT WEIGHT 2.200 OUNCES
III SPECIAL HANDLING FEATURE MAGNETIC
III FRAGILITY FACTOR MODERATELY RUGGED

Restrictions/Controls & Freight Information | NSN 5925-01-158-9056

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5925-01-158-9056

Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code5Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency.
Materiel Management CodeBAll CommoditiesDefense Logistics Agency, (DLA,)
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each