Product Details | CIRCUIT BREAKER

5925-01-209-1824 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: APGN66690943, APGN-666-9094-3, 408682, 5925-01-209-1824, 01-209-1824, 5925012091824, 012091824

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 24 MAY 1985 01-209-1824

Demand History | NSN 5925-01-209-1824

Part Number Request Date QTY Origin
408682 2020-03-86 4 DIBBS
APGN-666-9094-3 2020-03-86 4 DIBBS
408682 2020-03-75 4 DIBBS
APGN-666-9094-3 2020-03-75 4 DIBBS
5925-01-209-1824 2012-03-67 6 DIBBS
5925-01-209-1824 2008-08-233 6 DIBBS

Cross Reference | NSN 5925-01-209-1824

Part Number Cage Code Manufacturer
408682 12909 CARDION INC
408682 20284 TARGET CORPORATION DBA TARGET
APGN-666-9094-3 81541 SENSATA TECHNOLOGIES MARYLAND, INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-01-209-1824

Technical Data | NSN 5925-01-209-1824

Characteristic Specifications
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 10.000 MINIMUM AT 200 PCT THIRD LOCATION AND 70.000 MAXIMUM AT 200 PCT THIRD LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 3500.0 AC SECOND LOCATION
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
THREAD PITCH DIAMETERS +0.4752/+0.4787 INCHES
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 10.000 MINIMUM AT 200 PCT SECOND LOCATION AND 70.000 MAXIMUM AT 200 PCT SECOND LOCATION
NONTURN DEVICE LENGTH 0.130 INCHES NOMINAL
CASE MATERIAL PLASTIC
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC THIRD LOCATION
TERMINAL TYPE AND QUANTITY 6 TAB W/SCREW
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.232 INCHES MAXIMUM
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 65.0 DC FIRST LOCATION
THREAD QUANTITY PER INCH 32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 3.0 AMPERES AC SECOND LOCATION
BODY LENGTH 2.000 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SECOND LOCATION
NONTURN DEVICE RADIUS 0.656 INCHES NOMINAL
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 3500.0 AC THIRD LOCATION
NONTURN DEVICE DIAMETER 0.151 INCHES MINIMUM AND 0.161 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
THREAD SERIES DESIGNATOR UN
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT
NONTURN DEVICE LOCATION AT 12 OCLOCK AND AT 3 OCLOCK AND AT 9 OCLOCK
NOMINAL THREAD SIZE 0.500 INCHES
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 3.0 AMPERES AC THIRD LOCATION
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 6.0 AMPERES DC FIRST LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 ALL LOCATIONS
FRAGILITY FACTOR MODERATELY RUGGED
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000.0 DC FIRST LOCATION
FREQUENCY IN HERTZ 50.0 SECOND LOCATION OR 60.0 SECOND LOCATION
FREQUENCY IN HERTZ 50.0 THIRD LOCATION OR 60.0 THIRD LOCATION
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
ACTUATOR FUNCTION TRIP-RESET
POLE QUANTITY 3
ARC QUENCHING METHOD MAGNETIC BLOWOUT
RESET METHOD MANUAL
MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
BODY WIDTH 2.250 INCHES NOMINAL
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 20.000 MINIMUM AT 200 PCT FIRST LOCATION AND 70.000 MAXIMUM AT 200 PCT FIRST LOCATION
ACTUATOR POSITION DESIGNATION AT POLE TWO
SPECIAL HANDLING FEATURE MAGNETIC
UNPACKAGED UNIT WEIGHT 9.000 OUNCES
BUSHING LENGTH 0.625 INCHES NOMINAL
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.530 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5925-01-209-1824

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5925-01-209-1824

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationE The current standard price is an estimated price.
  • Estimated Price challenges are allowed, but follow procedures in para 60.b. (3) of section L of this manual.
  • This code will be changed to a P code upon notification of a contract price or this code will be changed to an updated code upon determination of a valid price.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each