Product Details | CIRCUIT BREAKER

5925-01-212-0118 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: APL21150553, APL-211-5055-3, 6010632003, 6010632-003, 5925-01-212-0118, 01-212-0118, 5925012120118, 012120118

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 05 JUL 1985 01-212-0118

Demand History | NSN 5925-01-212-0118

Part Number Request Date QTY Origin
5925-01-212-0118 2012-05-125 4 DIBBS
5925-01-212-0118 2012-03-83 7 DIBBS
5925-01-212-0118 2012-01-30 1 DIBBS
5925-01-212-0118 2009-06-170 2 DIBBS
5925-01-212-0118 2007-04-116 1 DIBBS

Cross Reference | NSN 5925-01-212-0118

Part Number Cage Code Manufacturer
6010632-003 12436 BAE SYSTEMS NATIONAL SECURITY SOLUTIONS INC.
APL-211-5055-3 81541 SENSATA TECHNOLOGIES MARYLAND, INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-01-212-0118

Technical Data | NSN 5925-01-212-0118

Characteristic Specifications
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES AC SECOND LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120.0 DC FIRST LOCATION
MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES AC AND 25.0 AMPERES DC FIRST LOCATION
NOMINAL THREAD SIZE 0.138 INCHES
CASE MATERIAL PLASTIC
MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED GENERAL PURPOSE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.667 INCHES NOMINAL AND 1.940 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.060 INCHES NOMINAL
BODY LENGTH 2.490 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 277.0 AC SECOND LOCATION
THREAD SERIES DESIGNATOR UNC
TERMINAL TYPE AND QUANTITY 8 THREADED STUD
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES AC THIRD LOCATION
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC THIRD LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 3.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT SECOND LOCATION
ACTUATOR POSITION DESIGNATION AT EACH POLE
TRIP RELEASE CHARACTERISTIC TIME DELAY SECOND LOCATION
FRAGILITY FACTOR MODERATELY RUGGED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL
TRIP RELEASE CHARACTERISTIC TIME DELAY THIRD LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC AND 5000.0 DC FIRST LOCATION
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
INTERNAL TRIP RELEASE CONFIGURATION RELAY TRIP FIRST LOCATION
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
ACTUATOR FUNCTION TRIP-RESET
POLE QUANTITY 3
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 3.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT THIRD LOCATION
RESET METHOD MANUAL
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 138.0 ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC SECOND LOCATION
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SECOND LOCATION
BODY WIDTH 2.250 INCHES NOMINAL
FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 277.0 AC THIRD LOCATION
TRIP RELEASE CHARACTERISTIC INSTANTANEOUS FIRST LOCATION
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP THIRD LOCATION
BOSS HEIGHT 0.150 INCHES NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.475 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5925-01-212-0118

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5925-01-212-0118

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationE The current standard price is an estimated price.
  • Estimated Price challenges are allowed, but follow procedures in para 60.b. (3) of section L of this manual.
  • This code will be changed to a P code upon notification of a contract price or this code will be changed to an updated code upon determination of a valid price.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1