Product Details | CIRCUIT BREAKER

5925-01-225-9333 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: JA3Z3012, JA3-Z-301-2, UPGH66729951, UPGH667-2995-1, 56002002, 56-002-002, 5925-01-225-9333, 01-225-9333, 5925012259333, 012259333

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 09 FEB 1986 01-225-9333

Cross Reference | NSN 5925-01-225-9333

Part Number Cage Code Manufacturer
56-002-002 89022 TDK-LAMBDA AMERICAS INC. DIV HIGH POWER DIVISION
JA3-Z-301-2 74193 EATON CORP HEINEMANN PRODUCTS
UPGH667-2995-1 81541 SENSATA TECHNOLOGIES MARYLAND, INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-01-225-9333

Technical Data | NSN 5925-01-225-9333

Characteristic Specifications
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.531 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 5.0 AMPERES AC THIRD LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SECOND LOCATION
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
NOMINAL THREAD SIZE 0.138 INCHES
SPECIAL FEATURES RELAY COIL HAS A SPECIAL ELECTRICAL SHORT FOR MECHANICAL TRIP
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP FIRST LOCATION
CASE MATERIAL PLASTIC
MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 25.0 AMPERES AC SECOND LOCATION
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED GENERAL PURPOSE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
THREAD QUANTITY PER INCH 32
TERMINAL TYPE AND QUANTITY 6 SCREW
THREAD SERIES DESIGNATOR UNC
BODY LENGTH 2.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.750 INCHES NOMINAL
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC INSTANTANEOUS THIRD LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.656 INCHES NOMINAL
FEATURES PROVIDED HIGH INRUSH PROTECTION
BUSHING LENGTH 0.130 INCHES NOMINAL
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS
MOUNTING SURFACE TO TERMINAL END DISTANCE 1.898 INCHES NOMINAL
ACTUATOR POSITION DESIGNATION AT EACH POLE
TRIP RELEASE CHARACTERISTIC TIME DELAY SECOND LOCATION
FREQUENCY IN HERTZ 50.0 OR 60.0 ALL LOCATIONS
FRAGILITY FACTOR MODERATELY RUGGED
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.750 INCHES NOMINAL
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
ACTUATOR FUNCTION TRIP-RESET
POLE QUANTITY 3
ARC QUENCHING METHOD MAGNETIC BLOWOUT
RESET METHOD MANUAL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 25.0 AMPERES AC FIRST LOCATION
TRIP RELEASE CHARACTERISTIC TIME DELAY FIRST LOCATION
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SECOND LOCATION
BODY WIDTH 2.250 INCHES NOMINAL
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
SPECIAL HANDLING FEATURE MAGNETIC
INTERNAL TRIP RELEASE CONFIGURATION RELAY TRIP THIRD LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT FIRST LOCATION

Restrictions/Controls & Freight Information | NSN 5925-01-225-9333

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5925-01-225-9333

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Special Material Content9 Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each