Product Details | CIRCUIT BREAKER

5925-01-227-6859 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Part Alternates: UPL111161153M, UPL-111-1-61-153-M, 499-041-078, 40066192, 4006619-2, 5925-01-227-6859, 01-227-6859, 5925012276859, 012276859, 499041078

Electrical and Electronic Equipment Components | Circuit Breakers

Supply Group (FSG) NSN Assign. NIIN
59 07 MAR 1986 01-227-6859

Cross Reference | NSN 5925-01-227-6859

Part Number Cage Code Manufacturer
4006619-2 29381 GICHNER SYSTEMS GROUP, INC. DBA GICHNER SHELTER SYSTEMS
499-041-078 07421 INTERSTATE ELECTRONICS CORPORATION DBA L-3 INTERSTATE ELECTRONICS
UPL-111-1-61-153-M 81541 SENSATA TECHNOLOGIES MARYLAND, INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5925-01-227-6859

Technical Data | NSN 5925-01-227-6859

Characteristic Specifications
BODY LENGTH 2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
STORAGE TYPE GENERAL PURPOSE WAREHOUSE
NOMINAL THREAD SIZE 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120.0 AC ALL LOCATIONS
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT
BOSS HEIGHT 0.135 INCHES MINIMUM AND 0.165 INCHES MAXIMUM
CASE MATERIAL PLASTIC
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES AC ALL LOCATIONS
MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
MOUNTING SURFACE TO TERMINAL END DISTANCE 2.490 INCHES MAXIMUM
THREAD QUANTITY PER INCH 32
THREAD SERIES DESIGNATOR UNC
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.180 MINIMUM AT 200 PCT AND 1.800 MAXIMUM AT 200 PCT ALL LOCATIONS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM
UNPACKAGED UNIT WEIGHT 11.100 OUNCES
ACTUATOR POSITION DESIGNATION AT EACH POLE
TERMINAL TYPE AND QUANTITY 6 THREADED STUD
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
FREQUENCY IN HERTZ 50.0 OR 60.0 ALL LOCATIONS
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
FRAGILITY FACTOR MODERATELY RUGGED
TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
ACTUATOR FUNCTION TRIP-RESET
POLE QUANTITY 3
ARC QUENCHING METHOD MAGNETIC BLOWOUT
RESET METHOD MANUAL
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC ALL LOCATIONS
SPECIAL HANDLING FEATURE MAGNETIC
BODY WIDTH 2.265 INCHES MAXIMUM
INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS

Restrictions/Controls & Freight Information | NSN 5925-01-227-6859

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code HD Naval Inventory Control Point
Mechanicsburg, PA 17055-0788
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5925-01-227-6859

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Special Material Content9 Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each