NSN 5925-01-528-4909 IELHK11-1REC5-62-35.0-A-01-V, IELHK111REC562350A01V, 01-528-4909
Product Details | CIRCUIT BREAKER
5925-01-528-4909 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Part Alternates: IELHK11-1REC5-62-35.0-A-01-V, IELHK111REC562350A01V, 5925-01-528-4909, 01-528-4909, 5925015284909, 015284909
Electrical and Electronic Equipment Components | Circuit Breakers
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 15 MAR 2005 | 01-528-4909 | 00136 ( CIRCUIT BREAKER ) |
Cross Reference | NSN 5925-01-528-4909
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| IELHK11-1REC5-62-35.0-A-01-V | 81541 | SENSATA TECHNOLOGIES MARYLAND, INC |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5925-01-528-4909
Technical Data | NSN 5925-01-528-4909
| Characteristic | Specifications |
|---|---|
| POLE QUANTITY | 2 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 12.0 AMPERES DC SINGLE LOCATION |
| FREQUENCY IN HERTZ | 50.0 OR 60.0 ALL LOCATIONS |
| TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
| TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| BODY STYLE | 2B MULTIPOLE-SINGLE ACTUATOR TYPE |
| BUSHING LENGTH | 0.140 INCHES NOMINAL |
| BODY LENGTH | 2.502 INCHES NOMINAL |
| BODY WIDTH | 1.859 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.940 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.060 INCHES NOMINAL |
| THREAD SERIES DESIGNATOR | M |
| SPECIAL FEATURES | VDE APPROVED; AUXILLARY SWITCH; 0.187 QUICK DISCONNECT; LONG DELAY |
Restrictions/Controls & Freight Information | NSN 5925-01-528-4909
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||