Product Details | THERMOSTATIC SWITCH

5930-00-081-4812 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: A106007, A10-6007, A301659, A30-1659, A30301, A30-301, KWS414, P6409, 25070, 5930-00-081-4812, 00-081-4812, 5930000814812, 000814812

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 08 DEC 1967 00-081-4812

Demand History | NSN 5930-00-081-4812

Part Number Request Date QTY Origin
25070 2014-06-157 5 US

Cross Reference | NSN 5930-00-081-4812

Part Number Cage Code Manufacturer
25070 70334 ALTER HARRY CO THE DIV OF T E C
A10-6007 49742 RANCO MANAGEMENT CORP
A30-1659 50992 RANCO INC RANCO CONTROLS DIV
A30-301 49742 RANCO MANAGEMENT CORP
A30-301 50992 RANCO INC RANCO CONTROLS DIV
KWS414 49742 RANCO MANAGEMENT CORP
KWS414 50992 RANCO INC RANCO CONTROLS DIV
P6409 99887 NELSON MFG CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-00-081-4812

Technical Data | NSN 5930-00-081-4812

Characteristic Specifications
CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE -24.00 TO 20.50 ACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE EXTERNAL ACTUATION POINT KNOB
CONTACT VOLTAGE RATING IN VOLTS 240.0 AC AT SEA LEVEL FIRST VOLTAGE 277.0 AC AT SEA LEVEL SECOND VOLTAGE
CONTACT LOAD CURRENT RATING 20.0 AMPERES MOTOR LOAD FIRST VOLTAGE 16.0 AMPERES MOTOR LOAD SECOND VOLTAGE
MEDIA FOR WHICH DESIGNED GAS OR LIQUID
TEMP SENSING ELEMENT TYPE CAPILLARY TUBE
CAPILLARY TUBE LENGTH 84.0 INCHES NOMINAL
TERMINAL TYPE TAB W/SCREW
MOUNTING METHOD BRACKET

Restrictions/Controls & Freight Information | NSN 5930-00-081-4812

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code 88 Goddard Space Center
Greenbelt, MD 20771-0001
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5930-00-081-4812

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code2Non-Critical Repair Part. Repair parts or major components whose failure in an end item will not render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency, and which do not fit the definition of Code 3 or 4 items.
Materiel Management CodeBAll CommoditiesDefense Logistics Agency, (DLA,)
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each