NSN 5930-00-247-3057 DR383, 00-247-3057, 002473057
Product Details | THERMOSTATIC SWITCH
5930-00-247-3057 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Part Alternates: DR383, 5930-00-247-3057, 00-247-3057, 5930002473057, 002473057
Electrical and Electronic Equipment Components | Switches
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 09 JUL 1969 | 00-247-3057 | 00451 ( SWITCH, THERMOSTATIC ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5930-00-247-3057
Related Products | NSN 5930-00-247-3057
Technical Data | NSN 5930-00-247-3057
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 2.125 INCHES NOMINAL |
| OVERALL DIAMETER | 5.750 INCHES NOMINAL |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
| CONTACT ADJUSTMENT RANGE | 50.00 TO 150.00 ACTUATION POINT DEGREES FAHRENHEIT AND 50.00 TO 150.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT STIMULUS RATING | 6.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
| CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SINGLE VOLTAGE |
| CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| CAPILLARY TUBE LENGTH | 72.000 INCHES NOMINAL |
| BULB LENGTH | 12.375 INCHES NOMINAL |
| BULB DIAMETER | 0.688 INCHES NOMINAL |
| TERMINAL TYPE | TAB W/SCREW |
| MOUNTING METHOD | FLANGE |
| MOUNTING FACILITY CIRCLE RADIUS | 3.250 INCHES NOMINAL |
| SPECIAL FEATURES | 6 FEET CAPILLARY TUBE GALVANIZED,HAND RESET |
| MANUFACTURERS CODE | 39709 |
| DESIGN CONTROL REFERENCE | DR383 |
Restrictions/Controls & Freight Information | NSN 5930-00-247-3057
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||