Product Details | THERMOSTATIC SWITCH

5930-00-448-6281 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: 291L3501402 , 31003462, 3100-3-462, 4344144, 4344-144, 71520171, 7152017-1, 5930-00-448-6281, 00-448-6281, 5930004486281, 004486281

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 18 FEB 1972 00-448-6281

Drawings & Photos | NSN 5930-00-448-6281


Demand History | NSN 5930-00-448-6281

Part Number Request Date QTY Origin
4344144 2010-09-273 10 CL

Cross Reference | NSN 5930-00-448-6281

Part Number Cage Code Manufacturer
291L3501402 U0AZ9 DYTECNA LTD DIV DYTECNA ENGINEERING
291L3501402 U3361 EBERSPACHER UK LTD
3100-3-462 14604 HONEYWELL INTERNATIONAL INC. DBA HONEYWELL
4344-144 01295 TEXAS INSTRUMENTS INCORPORATED DBA TEXAS INSTRUMENTS
7152017-1 10236 ELECTRODYNAMICS, INC. DBA L-3 COMMUNICATIONS
7152017-1 82647 SENSATA TECHNOLOGIES, INC DIV SENSATA ATTLEBORO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-00-448-6281

Technical Data | NSN 5930-00-448-6281

Characteristic Specifications
STYLE DESIGNATOR 64 DISC W/FLANGE
OVERALL LENGTH 1.250 INCHES NOMINAL
OVERALL HEIGHT 0.526 INCHES MAXIMUM
OVERALL WIDTH 0.640 INCHES MAXIMUM
BODY HEIGHT 0.395 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATING 67.00 ACTUATION POINT MINIMUM DEGREES CELSIUS AND 77.00 ACTUATION POINT MAXIMUM DEGREES CELSIUS AND 47.00 DEACTUATION POINT MINIMUM DEGREES CELSIUS AND 57.00 DEACTUATION POINT MAXIMUM DEGREES CELSIUS AND 15.00 DIFFERENTIAL POINT MINIMUM DEGREES CELSIUS AND 25.00 DIFFERENTIAL POINT MAXIMUM DEGREES CELSIUS
CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL FIRST VOLTAGE 28.0 DC AT SEA LEVEL SECOND VOLTAGE
FREQUENCY IN HERTZ 60.0 FIRST VOLTAGE
CONTACT LOAD CURRENT RATING 2.0 AMPERES RESISTIVE LOAD AND 500.0 MILLIAMPERES INDUCTIVE LOAD FIRST VOLTAGE 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD SECOND VOLTAGE
MEDIA FOR WHICH DESIGNED GAS OR LIQUID
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
TERMINAL TYPE TAB, SOLDER LUG
MOUNTING METHOD BRACKET
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 0.937 INCHES NOMINAL
TEST DATA DOCUMENT 96906-MIL-STD-202 SPECIFICATION

Restrictions/Controls & Freight Information | NSN 5930-00-448-6281

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable