NSN 5930-00-615-5148 604GB1160PSI, 604GB11-60PSI, 604GBJR1160PSI
Product Details | PRESSURE SWITCH
5930-00-615-5148 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Part Alternates: 604GB1160PSI, 604GB11-60PSI, 604GBJR1160PSI, 604GBJR11-60PSI, 5930-00-615-5148, 00-615-5148, 5930006155148, 006155148
Electrical and Electronic Equipment Components | Switches
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 12 FEB 1975 | 00-615-5148 | 00206 ( SWITCH, PRESSURE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5930-00-615-5148
Related Products | NSN 5930-00-615-5148
Technical Data | NSN 5930-00-615-5148
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 32 RECTANGULAR W/BRACKET |
| OVERALL LENGTH | 6.230 INCHES NOMINAL |
| OVERALL HEIGHT | 3.100 INCHES NOMINAL |
| OVERALL WIDTH | 4.750 INCHES NOMINAL |
| BODY LENGTH | 3.600 INCHES NOMINAL |
| BODY WIDTH | 4.000 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE, PRESET |
| CONTACT ADJUSTMENT RANGE | 20.00 TO 100.00 ACTUATION POINT POUNDS PER SQUARE INCH AND 14.00 TO 94.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
| CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW WITH SCALE |
| CONTACT STIMULUS RATING | 60.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 6.00 DIFFERENTIAL POINT NOMINAL POUNDS PER SQUARE INCH |
| CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL FIRST VOLTAGE 125.0 AC AT SEA LEVEL SECOND VOLTAGE 125.0 DC AT SEA LEVEL THIRD VOLTAGE 28.0 DC AT SEA LEVEL FOURTH VOLTAGE |
| FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
| CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 15.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE 400.0 MILLIAMPERES RESISTIVE LOAD THIRD VOLTAGE 6.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| PROOF PRESSURE | 4500.00 POUNDS PER SQUARE INCH |
| PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL SINGLE CONNECTION |
| INSIDE DIAMETER | 0.500 INCHES NOMINAL SINGLE CONNECTION |
| TERMINAL TYPE | SCREW |
| MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.265 INCHES NOMINAL |
| MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 4.250 INCHES NOMINAL |
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.100 INCHES NOMINAL |
| THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |
| NOMINAL THREAD SIZE | 0.500 INCHES SINGLE PRESSURE CONNECTION |
| THREAD QUANTITY PER INCH | 14 SINGLE PRESSURE CONNECTION |
| FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
| III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WEATHERPROOF |
Restrictions/Controls & Freight Information | NSN 5930-00-615-5148
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 658 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5930-00-615-5148
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |