Product Details | SWITCH ASSEMBLY

5930-00-723-2741 Two or more complete switches mounted on each other or having a common mounting the major function of which is to hold the switches. Each switch, as a separable item, must be capable of functioning in accordance with its own name. Excludes items consisting of individually separable switches which are physically interlocked (e.g., one button returns when the other is pushed), which have a common actuator, or are electrically connected. See also SWITCH, PUSH.

Part Alternates: 21511, 3071, 307-1, 6848091, 6-84809-1, 5930-00-723-2741, 00-723-2741, 5930007232741, 007232741

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1961 00-723-2741

Drawings & Photos | NSN 5930-00-723-2741


Demand History | NSN 5930-00-723-2741

Part Number Request Date QTY Origin
3071 2018-10-284 100 RO
21511 2010-03-76 2 United States

Cross Reference | NSN 5930-00-723-2741

Part Number Cage Code Manufacturer
21511 82647 SENSATA TECHNOLOGIES, INC DIV SENSATA ATTLEBORO
307-1 13539 C & H HYDRAULICS, INC DBA ACME DIVAC INDUSTRIES USE CAGE
6-84809-1 0JRC1 NORTHROP GRUMMAN TECHNICAL SERVICES, INC.
6-84809-1 76823 NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN AEROSPACE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-00-723-2741

Technical Data | NSN 5930-00-723-2741

Characteristic Specifications
INDIVIDUAL SWITCH QUANTITY 4
SWITCH TYPE SENSITIVE
CONTROLLING AGENCY MIL
IDENTIFYING NUMBER MS24456
OVERALL LENGTH 4.125 INCHES NOMINAL
OVERALL WIDTH 1.500 INCHES NOMINAL
OVERALL HEIGHT 2.688 INCHES NOMINAL
MOUNTING METHOD BRACKET
MOUNTING CONFIGURATION TWO MTG HOLES O.193 IN. DIA SPACED 2.000 IN. C TO C
III FSC APPLICATION DATA SWITCH ASSY,MULTIAPPLICATION,EXCEPT ANTENNA AND TRANSMISSION LINE
MANUFACTURERS CODE 76823
DESIGN CONTROL REFERENCE 6-84809-1

Restrictions/Controls & Freight Information | NSN 5930-00-723-2741

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable