Product Details | INERTIA SWITCH

5930-00-972-0544 A switch which is specifically designed to be actuated by an abrupt change in velocity of the item upon which it is mounted.

Part Alternates: 10B019G1, 721898-043, 5930-00-972-0544, 00-972-0544, 5930009720544, 009720544, 721898043

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1960 00-972-0544

Drawings & Photos | NSN 5930-00-972-0544


Cross Reference | NSN 5930-00-972-0544

Part Number Cage Code Manufacturer
10B019G1 60365 TORQ ELECTRIC CORP
721898-043 05869 RAYTHEON COMPANY DBA RAYTHEON
721898-043 82577 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-00-972-0544

Technical Data | NSN 5930-00-972-0544

Characteristic Specifications
STYLE DESIGNATOR 9 CYLINDRICAL W/FLANGE
OVERALL HEIGHT 3.760 INCHES NOMINAL
BODY HEIGHT 3.380 INCHES NOMINAL
OVERALL DIAMETER 2.650 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATING 1800.00 ACTUATION POINT NOMINAL REVOLUTIONS PER MINUTE AND 900.00 DEACTUATION POINT NOMINAL REVOLUTIONS PER MINUTE
CONTACT VOLTAGE RATING IN VOLTS 120.0 AC AT SEA LEVEL FIRST VOLTAGE 30.0 DC AT SEA LEVEL SECOND VOLTAGE
FREQUENCY IN HERTZ 60.0 FIRST VOLTAGE
CONTACT LOAD CURRENT RATING 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
TERMINAL TYPE WIRE LEAD
MOUNTING METHOD FLANGE
MOUNTING FACILITY PATTERN THREE POSITION CIRCULAR
MOUNTING FACILITY CIRCLE RADIUS 1.125 INCHES NOMINAL
MANUFACTURERS CODE 05869
DESIGN CONTROL REFERENCE 721898-043

Restrictions/Controls & Freight Information | NSN 5930-00-972-0544

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5930-00-972-0544

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each