Product Details | THERMOSTATIC SWITCH

5930-01-012-3903 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: 5930-01-012-3903, 01-012-3903, 5930010123903, 010123903

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 01-012-3903

Drawings & Photos | NSN 5930-01-012-3903


Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-012-3903

Technical Data | NSN 5930-01-012-3903

Characteristic Specifications
STYLE DESIGNATOR 77 RECTANGULAR W/BRACKET
OVERALL LENGTH 1.323 INCHES MAXIMUM
OVERALL HEIGHT 0.604 INCHES MAXIMUM
OVERALL WIDTH 0.405 INCHES MAXIMUM
BODY LENGTH 0.750 INCHES NOMINAL
BODY WIDTH 0.405 INCHES MAXIMUM
BODY HEIGHT 0.344 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATING 63.00 ACTUATION POINT MINIMUM DEGREES CELSIUS AND 73.00 ACTUATION POINT MAXIMUM DEGREES CELSIUS
CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL FIRST VOLTAGE 28.0 DC AT SEA LEVEL SECOND VOLTAGE
CONTACT LOAD CURRENT RATING 2.5 AMPERES RESISTIVE LOAD FIRST VOLTAGE 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
OPERATING TEMP RATING 220.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
TERMINAL TYPE TAB, SOLDER LUG
MOUNTING METHOD BRACKET
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.016 INCHES NOMINAL
III END ITEM IDENTIFICATION TRANSMISSOMETER SYSTEM, FA9471/9472 (RVR500)

Restrictions/Controls & Freight Information | NSN 5930-01-012-3903

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information