Product Details | LIQUID LEVEL SWITCH

5930-01-136-1487 A switch which is actuated by a float or sensing device(s) to control liquid level and/or actuate visual or audible warning systems. It may include a relay controlled by the switch element. Excludes TRANSMITTER,LIQUID QUANTITY.20429100042Engine Fuel System Components, Nonaircraft29150064Engine Fuel System Components, Aircraft and Missile Prime Movers59300008Switches66800078Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments

Part Alternates: LS12790, LS-12790, LS127908, LS-12790-8, 46439, 5930-01-136-1487, 01-136-1487, 5930011361487, 011361487

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 01-136-1487

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-136-1487

Technical Data | NSN 5930-01-136-1487

Characteristic Specifications
AC VOLTAGE RATING 110.0 VOLTS NOMINAL 120.0 VOLTS NOMINAL
FREQUENCY RATING 60.0 HERTZ NOMINAL 60.0 HERTZ NOMINAL
PHASE SINGLE SINGLE
CURRENT RATING AT MAXIMUM RATED VOLTAGE 0.04 AMPERES RESISTIVE LOAD
MAXIMUM CURRENT RATING 0.08 AMPERES RESISTIVE LOAD
VOLTAGE RATING AT MAXIMUM RATED CURRENT 110.0 VOLTS
CONTACT ARRANGEMENT SPDT
ELECTRICAL CONNECTION TYPE TERMINAL BLOCK
RELAY NOT INCLUDED
LIQUID TYPE FOR WHICH DESIGNED RADIATION CONTAMINATED WATER
OPERATING TEMP RATING -65.0 DEG FAHRENHEIT MINIMUM AND 300.0 DEG FAHRENHEIT MAXIMUM
ACTUATION METHOD BUOYANCY
FLOAT QUANTITY 1
FLOAT EFFECTIVE TRAVEL ANY ACCEPTABLE
MOUNTING POSITION VERTICAL
MOUNTING METHOD FLANGE
MOUNTING DIMENSIONS MTD BY FOUR 5/8 IN. DIA HOLES EQUALLY SPACED ON A 3-1/2 IN. DIA BOLT CIRCLE
OVERALL LENGTH ANY ACCEPTABLE
OVERALL DIAMETER 4.625 INCHES NOMINAL
TANK INSERTION LENGTH 7.250 INCHES NOMINAL
SPECIAL FEATURES SILVER BRAZED FOUR PLACES BETWEEN JUNCTION BOX AND BRACKET WELDMENT
MANUFACTURERS CODE 04034
DESIGN CONTROL REFERENCE 46439

Restrictions/Controls & Freight Information | NSN 5930-01-136-1487

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information