Product Details | PRESSURE SWITCH

5930-01-144-0460 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Part Alternates: 6607A843, 6607A-8-43, 5930-01-144-0460, 01-144-0460, 5930011440460, 011440460

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 13 DEC 1982 01-144-0460

Cross Reference | NSN 5930-01-144-0460

Part Number Cage Code Manufacturer
6607A-8-43 02750 EATON AEROSPACE LLC DIV ELECTRICAL SENSING & CONTROLS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-144-0460

Technical Data | NSN 5930-01-144-0460

Characteristic Specifications
OVERALL LENGTH 3.340 INCHES MAXIMUM
BODY DIAMETER 1.390 INCHES MAXIMUM
OVERALL DIAMETER 1.390 INCHES MAXIMUM
PRESSURE SWITCH TYPE GAGE
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE 800.00 TO 2000.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE
CONTACT ADJUSTMENT TYPE INTERNAL ACTUATION POINT SCREW
CONTACT VOLTAGE RATING IN VOLTS 250.0 AC AT SEA LEVEL FIRST VOLTAGE 125.0 AC AT SEA LEVEL SECOND VOLTAGE 30.0 DC AT SEA LEVEL THIRD VOLTAGE 30.0 DC AT ALTITUDE FOURTH VOLTAGE
CONTACT LOAD CURRENT RATING 5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE 2.5 AMPERES INDUCTIVE LOAD THIRD VOLTAGE 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE
OPERATING TEMP RATING -65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED GAS OR LIQUID
PROOF PRESSURE 4500.00 POUNDS PER SQUARE INCH GAGE
PRESSURE CONNECTOR TYPE FLARE, THREADED INTERNAL SINGLE CONNECTION
TERMINAL TYPE CONNECTOR, RECEPTACLE
MOUNTING METHOD CLAMP
THREAD SERIES DESIGNATOR UNF SINGLE PRESSURE CONNECTION
NOMINAL THREAD SIZE 0.437 INCHES SINGLE PRESSURE CONNECTION
THREAD CLASS 3B SINGLE PRESSURE CONNECTION
THREAD QUANTITY PER INCH 20 SINGLE PRESSURE CONNECTION
III SENSING ELEMENT BURST PRESSURE 7500.00 POUNDS PER SQUARE INCH GAGE

Restrictions/Controls & Freight Information | NSN 5930-01-144-0460

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code ZF France
ZG
ZH
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable