NSN 5930-01-185-9820 CFG4R4CEL, 01-185-9820, 011859820
Product Details | PRESSURE SWITCH
5930-01-185-9820 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.
Part Alternates: CFG4R4CEL, 5930-01-185-9820, 01-185-9820, 5930011859820, 011859820
Electrical and Electronic Equipment Components | Switches
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 06 AUG 1984 | 01-185-9820 | 00206 ( SWITCH, PRESSURE ) |
Cross Reference | NSN 5930-01-185-9820
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| CFG4R4CEL | 85814 | NASON COMPANY, THE INC |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5930-01-185-9820
Related Products | NSN 5930-01-185-9820
Technical Data | NSN 5930-01-185-9820
| Characteristic | Specifications |
|---|---|
| STYLE DESIGNATOR | 41 CYLINDRICAL |
| OVERALL LENGTH | 3.375 INCHES NOMINAL |
| WIDTH ACROSS FLATS | 0.750 INCHES NOMINAL |
| BODY LENGTH | 1.563 INCHES NOMINAL |
| OVERALL DIAMETER | 1.875 INCHES NOMINAL |
| PRESSURE SWITCH TYPE | GAGE |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CONTACT STIMULUS RATING | 4.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE AND 3.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL FIRST VOLTAGE 250.0 AC AT SEA LEVEL SECOND VOLTAGE 24.0 DC AT SEA LEVEL THIRD VOLTAGE |
| CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE 10.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| OPERATING TEMP RATING | 250.0 DEG CELSIUS MAXIMUM |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| PROOF PRESSURE | 250.00 POUNDS PER SQUARE INCH GAGE |
| PRESSURE CONNECTOR TYPE | FLARED, THREADED EXTERNAL SINGLE CONNECTION |
| OUTSIDE DIAMETER | 0.250 INCHES NOMINAL SINGLE CONNECTION |
| TERMINAL TYPE | WIRE LEAD |
| MOUNTING METHOD | INLET CONNECTION |
| THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |
| NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
| III SENSING ELEMENT BURST PRESSURE | 450.00 POUNDS PER SQUARE INCH GAGE |
Restrictions/Controls & Freight Information | NSN 5930-01-185-9820
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061400 | CONDENSERS/PARTS NOI/CAPACITORS |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5930-01-185-9820
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9N | Navy-owned stocks of defense electronic material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | S9E | Defense Supply Center Columbus Columbus, OH 43218 |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |