Product Details | THERMOSTATIC SWITCH

5930-01-193-1549 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: VE-3101/85 DEG C OPEN ON RISE, VE310185DEGCOPENONRISE, 42211023009, 42211-023-00-9, 5930-01-193-1549, 01-193-1549, 5930011931549, 011931549

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 30 OCT 1984 01-193-1549

Drawings & Photos | NSN 5930-01-193-1549


Cross Reference | NSN 5930-01-193-1549

Part Number Cage Code Manufacturer
42211-023-00-9 K4556 BRITISH AEROSPACE DEFENCE SYSTEMS LTD T/A BAE SYSTEMS
42211-023-00-9 KC1M9 BAE SYSTEMS MARITIME SERVICESLIMITED
VE-3101/85 DEG C OPEN ON RISE 93929 SPX CORPORATION DBA RADIODETECTION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-193-1549

Technical Data | NSN 5930-01-193-1549

Characteristic Specifications
STYLE DESIGNATOR 77 RECTANGULAR W/BRACKET
OVERALL LENGTH 1.266 INCHES MAXIMUM
OVERALL HEIGHT 0.688 INCHES MAXIMUM
OVERALL WIDTH 0.390 INCHES MAXIMUM
BODY LENGTH 0.750 INCHES MAXIMUM
BODY HEIGHT 0.438 INCHES NOMINAL
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATING 85.00 ACTUATION POINT NOMINAL DEGREES CELSIUS
CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL FIRST VOLTAGE 32.0 DC AT SEA LEVEL SECOND VOLTAGE
CONTACT LOAD CURRENT RATING 3.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
TERMINAL TYPE TAB, SOLDER LUG
MOUNTING METHOD SLOT
MOUNTING SLOT WIDTH 0.188 INCHES NOMINAL
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 0.484 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5930-01-193-1549

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information