Product Details | THERMOSTATIC SWITCH

5930-01-200-3693 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: NF9200423, NF9-20042-3, C300119276003, C-300-119276-003, 22210NL2222843, 222-10NL-2222843, 2222843NL, 222-2843NL, 5930-01-200-3693, 01-200-3693, 5930012003693, 012003693

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 04 FEB 1985 01-200-3693

Drawings & Photos | NSN 5930-01-200-3693


Demand History | NSN 5930-01-200-3693

Part Number Request Date QTY Origin
222-10NL-2222843 2026-01-22 15 DIBBS
C-300-119276-003 2026-01-22 15 DIBBS
NF9-20042-3 2026-01-22 15 DIBBS
222-10NL-2222843 2024-08-214 2 DIBBS
C-300-119276-003 2024-08-214 2 DIBBS
NF9-20042-3 2024-08-214 2 DIBBS
222-10NL-2222843 2024-05-130 3 DIBBS
C-300-119276-003 2024-05-130 3 DIBBS
NF9-20042-3 2024-05-130 3 DIBBS
222-10NL-2222843 2024-04-95 2 DIBBS
C-300-119276-003 2024-04-95 2 DIBBS
NF9-20042-3 2024-04-95 2 DIBBS
222-10NL-2222843 2023-12-361 2 DIBBS
C-300-119276-003 2023-12-361 2 DIBBS
NF9-20042-3 2023-12-361 2 DIBBS
222-10NL-2222843 2023-12-348 2 DIBBS
C-300-119276-003 2023-12-348 2 DIBBS
NF9-20042-3 2023-12-348 2 DIBBS
222-10NL-2222843 2023-08-243 2 DIBBS
C-300-119276-003 2023-08-243 2 DIBBS
NF9-20042-3 2023-08-243 2 DIBBS
222-10NL-2222843 2022-11-317 2 DIBBS
C-300-119276-003 2022-11-317 2 DIBBS
NF9-20042-3 2022-11-317 2 DIBBS
222-10NL-2222843 2022-04-111 6 DIBBS
C-300-119276-003 2022-04-111 6 DIBBS
NF9-20042-3 2022-04-111 6 DIBBS
5930-01-200-3693 2018-10-284 14 DIBBS
5930-01-200-3693 2014-04-100 17 DIBBS
5930-01-200-3693 2012-04-103 3 DIBBS
5930-01-200-3693 2012-03-90 2 DIBBS
5930-01-200-3693 2012-01-05 1 DIBBS
5930-01-200-3693 2009-11-313 3 DIBBS
5930-01-200-3693 2009-09-267 1 DIBBS
5930-01-200-3693 2009-09-264 2 DIBBS
5930-01-200-3693 2008-07-183 2 DIBBS

Cross Reference | NSN 5930-01-200-3693

Part Number Cage Code Manufacturer
222-10NL-2222843 19278 DETROIT SWITCH, INC.
222-2843NL 19278 DETROIT SWITCH, INC.
C-300-119276-003 65586 CHROMALOX, INC. DBA OGDEN
NF9-20042-3 88234 UNITED ELECTRIC CONTROLS COMPANY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-200-3693

Technical Data | NSN 5930-01-200-3693

Characteristic Specifications
STYLE DESIGNATOR 35 RECTANGULAR
OVERALL LENGTH 5.188 INCHES NOMINAL
OVERALL WIDTH 2.812 INCHES NOMINAL
BODY HEIGHT 2.750 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE
CONTACT ADJUSTMENT RANGE 90.00 TO 165.00 ACTUATION POINT DEGREES FAHRENHEIT AND 2.00 TO 5.00 DEACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE EXTERNAL ACTUATION POINT HEX NUT
CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL FIRST VOLTAGE 550.0 AC AT SEA LEVEL SECOND VOLTAGE 115.0 DC AT SEA LEVEL THIRD VOLTAGE 550.0 DC AT SEA LEVEL FOURTH VOLTAGE
FREQUENCY IN HERTZ 60.0 FIRST VOLTAGE 60.0 SECOND VOLTAGE
CONTACT LOAD CURRENT RATING 16.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 3.2 AMPERES RESISTIVE LOAD SECOND VOLTAGE 9.6 AMPERES RESISTIVE LOAD THIRD VOLTAGE 2.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE
MEDIA FOR WHICH DESIGNED GAS OR LIQUID
TEMP SENSING ELEMENT TYPE CAPILLARY TUBE-BULB
CAPILLARY TUBE LENGTH 120.0 INCHES NOMINAL
BULB LENGTH 3.625 INCHES NOMINAL
BULB DIAMETER 0.688 INCHES NOMINAL
TERMINAL TYPE SCREW
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER 0.281 INCHES NOMINAL
MOUNTING FACILITY PATTERN OBTUSE TRIANGLE
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 2.406 INCHES NOMINAL
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 0.656 INCHES NOMINAL
SHORTEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS 3.281 INCHES NOMINAL
SPECIAL FEATURES BULB UP/CAP.TUBE DOWN
III PRECIOUS MATERIAL SILVER
III PRECIOUS MATERIAL AND LOCATION CONTACTS SILVER

Restrictions/Controls & Freight Information | NSN 5930-01-200-3693

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:SItem contains silver
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5930-01-200-3693

Category Code Description
Cognizance Codes3BNavy-owned stocks of field level repairable DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
ReparabilityDField Level Reparables
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each