Product Details | LIQUID LEVEL SWITCH

5930-01-216-5136 A switch which is actuated by a float or sensing device(s) to control liquid level and/or actuate visual or audible warning systems. It may include a relay controlled by the switch element. Excludes TRANSMITTER,LIQUID QUANTITY.20429100042Engine Fuel System Components, Nonaircraft29150064Engine Fuel System Components, Aircraft and Missile Prime Movers59300008Switches66800078Liquid and Gas Flow, Liquid Level, and Mechanical Motion Measuring Instruments

Part Alternates: LS542802, LS-54280-2, 54277, 5930-01-216-5136, 01-216-5136, 5930012165136, 012165136

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 12 SEP 1985 01-216-5136

Cross Reference | NSN 5930-01-216-5136

Part Number Cage Code Manufacturer
54277 04034 GEMS SENSORS INC.
LS-54280-2 04034 GEMS SENSORS INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-216-5136

Technical Data | NSN 5930-01-216-5136

Characteristic Specifications
RELAY NOT INCLUDED
OVERALL DIAMETER 6.125 INCHES NOMINAL
FLOAT QUANTITY 1
OPERATING TEMP RATING 65.0 DEG FAHRENHEIT MINIMUM AND 100.0 DEG FAHRENHEIT MAXIMUM
ELECTRICAL CONNECTION TYPE CABLE
MOUNTING METHOD FLANGE
LIQUID TYPE FOR WHICH DESIGNED HYDRAULIC OIL AND LUBRICATING OIL AND SEA WATER AND VARIOUS FUELS
OVERALL LENGTH 36.750 INCHES NOMINAL
ACTUATION METHOD BUOYANCY
MOUNTING POSITION VERTICAL

Restrictions/Controls & Freight Information | NSN 5930-01-216-5136

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5930-01-216-5136

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each