NSN 5930-01-225-8511 22210NN2223267, 222-10NN2223267, 01-225-8511
Product Details | THERMOSTATIC SWITCH
5930-01-225-8511 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Part Alternates: 22210NN2223267, 222-10NN2223267, 5930-01-225-8511, 01-225-8511, 5930012258511, 012258511
Electrical and Electronic Equipment Components | Switches
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 08 FEB 1986 | 01-225-8511 | 00451 ( SWITCH, THERMOSTATIC ) |
Demand History | NSN 5930-01-225-8511
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 5930-01-225-8511 | 2018-05-122 | 1 | DIBBS |
Cross Reference | NSN 5930-01-225-8511
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 222-10NN2223267 | 19278 | DETROIT SWITCH, INC. |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5930-01-225-8511
Related Products | NSN 5930-01-225-8511
Technical Data | NSN 5930-01-225-8511
| Characteristic | Specifications |
|---|---|
| LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL |
| CONTACT LOAD CURRENT RATING | 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE |
| OVERALL LENGTH | 5.188 INCHES NOMINAL |
| TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB |
| CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
| FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
| FREQUENCY IN HERTZ | 60.0 SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE |
| TERMINAL TYPE | SCREW |
| CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
| CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE |
| BODY HEIGHT | 2.750 INCHES NOMINAL |
| SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL |
| CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE |
| MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
| OVERALL WIDTH | 2.812 INCHES NOMINAL |
| CONTACT LOAD CURRENT RATING | 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
| MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
| CAPILLARY TUBE LENGTH | 120.0 INCHES NOMINAL |
| CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SIXTH VOLTAGE |
| CONTACT ADJUSTMENT RANGE | +140.00 TO 215.00 ACTUATION POINT DEGREES FAHRENHEIT |
| CONTACT ACTION STIMULUS | INCREASE |
| CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
| FREQUENCY IN HERTZ | 60.0 FOURTH VOLTAGE |
| LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.406 INCHES NOMINAL |
| BULB LENGTH | 6.500 INCHES NOMINAL |
| OVERALL HEIGHT | 5.937 INCHES NOMINAL |
| SPECIAL FEATURES | ARMORED |
| MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
| CONTACT VOLTAGE RATING IN VOLTS | 440.0 AC AT SEA LEVEL THIRD VOLTAGE |
| CONTACT LOAD CURRENT RATING | 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE |
| FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
| BULB DIAMETER | 1.125 INCHES NOMINAL |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF AND WATERTIGHT AND DUSTPROOF |
| NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
| STYLE DESIGNATOR | RECTANGULAR |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |
| CONTACT VOLTAGE RATING IN VOLTS | 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE |
| CONTACT LOAD CURRENT RATING | 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| FREQUENCY IN HERTZ | 60.0 THIRD VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FOURTH VOLTAGE |
| CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FIFTH VOLTAGE |
Restrictions/Controls & Freight Information | NSN 5930-01-225-8511
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 658 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5930-01-225-8511
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |