Product Details | CODE INDICATING WHEEL SWITCH

5930-01-280-0554 A switch which is externally actuated by a thumbwheel and/or pushbutton. A legend or message is visually displayed at each position of the indicating wheel which corresponds to electrically coded output. Electrically coded output is achieved by rotating a set of brush contacts permanently attached to the code indicating wheel, against a stationary commutator which is usually a printed wiring board having electrical pads or contacts which are interconnected by the rotating brush contacts. May have additional electrical components (such as resistors, capacitors, diodes) premounted on that portion of printed wiring board which extends beyond the back of switch housing.

Part Alternates: 6902500352, 690-2500-352, 5930-01-280-0554, 01-280-0554, 5930012800554, 012800554

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 29-MAY-88 01-280-0554

Drawings & Photos | NSN 5930-01-280-0554


Cross Reference | NSN 5930-01-280-0554

Part Number Cage Code Manufacturer
690-2500-352 44503 DATEX-OHMEDA INC DBA GE HEALTHCARE BIOSCIENCE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-280-0554

Technical Data | NSN 5930-01-280-0554

Characteristic Specifications
STYLE DESIGNATOR 30 RECTANGULAR INLINE INDICATING
OVERALL LENGTH 2.520 INCHES NOMINAL
OVERALL HEIGHT 0.988 INCHES NOMINAL
OVERALL WIDTH 0.945 INCHES NOMINAL
INDIVIDUAL SECTION QUANTITY 1
READOUT INDICATOR MARKING 1,2,3,4 SINGLE SECTION
ACTUATOR TYPE THUMBWHEEL ALL ACTUATORS
SWITCH ACTUATOR INDEXING POSITION QUANTITY 4 ALL ACTUATORS
TERMINAL TYPE PRINTED CIRCUIT
MOUNTING METHOD PRINTED CIRCUIT SINGLE MOUNTING FACILITY
SPECIAL FEATURES FOR USE W/ANESTHESIA APPARATUS-OXYGEN MONITOR,MDL 5120; UNIT QTY 2
III END ITEM IDENTIFICATION 6515-01-185-8446
MANUFACTURERS CODE 44503
DESIGN CONTROL REFERENCE 690-2500-352

Restrictions/Controls & Freight Information | NSN 5930-01-280-0554

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information