Product Details | THERMOSTATIC SWITCH

5930-01-369-8371 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: SC6553922, SC655392-2 , 3500364L97C, 3500-36-4-L97C, 5930-01-369-8371, 01-369-8371, 5930013698371, 013698371

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 07 JAN 1993 01-369-8371

Drawings & Photos | NSN 5930-01-369-8371


Cross Reference | NSN 5930-01-369-8371

Part Number Cage Code Manufacturer
3500-36-4-L97C 14604 HONEYWELL INTERNATIONAL INC. DBA HONEYWELL
SC655392-2 K3743 BAE SYSTEMS GLOBAL COMBAT SYSTEMS LIMITED
SC655392-2 K6894 BAE SYSTEMS RO DEFENCE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-369-8371

Technical Data | NSN 5930-01-369-8371

Characteristic Specifications
STYLE DESIGNATOR 64 DISC W/FLANGE
OVERALL LENGTH 1.375 INCHES NOMINAL
OVERALL HEIGHT 0.605 INCHES NOMINAL
BODY DIAMETER 0.605 INCHES MAXIMUM
BODY HEIGHT 0.290 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE, PRESET
CONTACT STIMULUS RATING 97.00 ACTUATION POINT NOMINAL DEGREES CELSIUS
CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL FIRST VOLTAGE 28.0 DC AT SEA LEVEL SECOND VOLTAGE
CONTACT LOAD CURRENT RATING 2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 0.5 AMPERES LAMP LOAD FIRST VOLTAGE 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE
MEDIA FOR WHICH DESIGNED GAS OR LIQUID
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
TERMINAL TYPE TAB, SOLDER LUG
MOUNTING METHOD BRACKET

Restrictions/Controls & Freight Information | NSN 5930-01-369-8371

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information