Product Details | THERMOSTATIC SWITCH

5930-01-412-6614 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: SC60A, SC-60-A, 5930-01-412-6614, 01-412-6614, 5930014126614, 014126614

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 25 APR 1995 01-412-6614

Drawings & Photos | NSN 5930-01-412-6614


Cross Reference | NSN 5930-01-412-6614

Part Number Cage Code Manufacturer
SC-60-A 59270 SELCO PRODUCTS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-412-6614

Technical Data | NSN 5930-01-412-6614

Characteristic Specifications
STYLE DESIGNATOR 64 DISC W/FLANGE
OVERALL LENGTH 1.187 INCHES NOMINAL
OVERALL HEIGHT 0.489 INCHES NOMINAL
BODY DIAMETER 0.625 INCHES NOMINAL
BODY HEIGHT 0.489 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT NOT ADJUSTABLE
CONTACT VOLTAGE RATING IN VOLTS 60.0 AC AT SEA LEVEL SINGLE VOLTAGE
CONTACT LOAD CURRENT RATING 15.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE
MEDIA FOR WHICH DESIGNED GAS
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
TERMINAL TYPE TAB, SOLDER LUG
MOUNTING METHOD BRACKET AND UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER 0.125 INCHES NOMINAL
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 0.937 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5930-01-412-6614

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information