Product Details | PRESSURE SWITCH

5930-01-455-5784 A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; and SWITCH, SENSITIVE.

Part Alternates: 12974421, 7606401-60, 5930-01-455-5784, 01-455-5784, 5930014555784, 014555784, 760640160

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 07 MAY 1998 01-455-5784

Cross Reference | NSN 5930-01-455-5784

Part Number Cage Code Manufacturer
12974421 U4310 VOLVO CONSTRUCTION EQUIPMENT LTD
7606401-60 74400 HOBBS CORP
7606401-60 91929 HONEYWELL INTERNATIONAL INC. DBA HONEYWELL

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-455-5784

Technical Data | NSN 5930-01-455-5784

Characteristic Specifications
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT VOLTAGE RATING IN VOLTS 24.0 DC AT SEA LEVEL FIRST VOLTAGE 240.0 AC AT SEA LEVEL SECOND VOLTAGE
MEDIA FOR WHICH DESIGNED LIQUID
PROOF PRESSURE 1250.00 POUNDS PER SQUARE INCH
TERMINAL TYPE QUICK DISCONNECT, MALE
MOUNTING METHOD BASE
SPECIAL FEATURES 4 TO 15 AMP RESISTIVE; 6 TO 24 VDC, DIRECT ACTION BLADE CONTACTS; 2 SCREW TERMS; OP PRESSURE 250 PSI; 51 TO 90 PSI CONTACT SETTING
III PRECIOUS MATERIAL SILVER AND GOLD
III PRECIOUS MATERIAL AND LOCATION CONTACT SURFACES SILVER AND CONTACT SURFACES GOLD

Restrictions/Controls & Freight Information | NSN 5930-01-455-5784

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:CItem contains two or more precious metals
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information