Product Details | THERMOSTATIC SWITCH

5930-01-488-6687 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Part Alternates: 03PP150051, 5930-01-488-6687, 01-488-6687, 5930014886687, 014886687

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 30 AUG 2001 01-488-6687

Drawings & Photos | NSN 5930-01-488-6687


Cross Reference | NSN 5930-01-488-6687

Part Number Cage Code Manufacturer
03PP150051 61492 NGT CONTROLS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-488-6687

Technical Data | NSN 5930-01-488-6687

Characteristic Specifications
STYLE DESIGNATOR 64 DISC W/FLANGE
OVERALL LENGTH 32.0 MILLIMETERS NOMINAL
OVERALL HEIGHT 12.0 MILLIMETERS NOMINAL
BODY DIAMETER 16.0 MILLIMETERS NOMINAL
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE
CONTACT VOLTAGE RATING IN VOLTS 120.0 AC AT SEA LEVEL FIRST VOLTAGE 30.0 DC AT SEA LEVEL SECOND VOLTAGE
OPERATING TEMP RATING 65.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
TEMP SENSING ELEMENT TYPE DISC
TERMINAL TYPE QUICK DISCONNECT, MALE
MOUNTING METHOD BRACKET
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 24.0 MILLIMETERS NOMINAL
FEATURES PROVIDED AUTOMATIC RESET
SPECIAL FEATURES IMPORTANT - WHEN ORDERING MUST SPECIFY OPERATING TEMPERATURE RANGE - OPEN 80 DEG. C. PLUS OR MINUS 5 DEG. C. - CLOSE 70 DEG. C. PLUS OR MINUS 5 DEG. C; PART NAME ASSIGNED BY CONTROLLING AGENCY - BIMETALLIC DISC THERMOSTAT; SHOCK RESISTANT; SINGLE POLE DOUBLE THROW; NORMALLY CLOSED; OPEN ON RISE; CONTACT POINT 1 TO 100 MILLIAMPS; PHENOLIC BODY; ALUMINUM OPEN CAP; STAINLESS STEEL ADJUSTABLE MOUNTING BRACKET
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION HUMIDITY RESISTANT AND VIBRATION RESISTANT

Restrictions/Controls & Freight Information | NSN 5930-01-488-6687

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information