Product Details | FLOW SWITCH

5930-01-519-4003 A switch which is specifically designed to operate by the influence of a gaseous, liquid, or solid media velocity on its actuator.

Part Alternates: SW112-REAC/DC24V-2M, SW112REACDC24V2M, PS224412.04, PS22441204, 5930-01-519-4003, 01-519-4003, 5930015194003, 015194003

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 16 APR 2004 01-519-4003

Drawings & Photos | NSN 5930-01-519-4003


Demand History | NSN 5930-01-519-4003

Part Number Request Date QTY Origin
PS22441204 2012-05-150 7 US
5930-01-519-4003 2011-03-90 1 US

Cross Reference | NSN 5930-01-519-4003

Part Number Cage Code Manufacturer
PS224412.04 35181 CAE INC
SW112-REAC/DC24V-2M 06402 OAKLAND INDUSTRIES LTD DBA E-T-A CIRCUIT BREAKERS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-519-4003

Technical Data | NSN 5930-01-519-4003

Characteristic Specifications
STYLE DESIGNATOR 4 CYLINDRICAL
OVERALL LENGTH 162.0 MILLIMETERS NOMINAL
WIDTH ACROSS FLATS 46.0 MILLIMETERS NOMINAL
OPERATING TEMP RATING -20.0 DEG CELSIUS MINIMUM AND 60.0 DEG CELSIUS MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 37.0 MILLIMETERS NOMINAL
SPECIAL FEATURES FLOW RATE RANGE, GASES 0.5 TO 20 M S; MEDIUM TEMP M20.0 TO 60.0 DEG C; PRESSURE RESISTANCE 1 BAR 14.7 PSI; ENVIRONMENTAL PROTECTION MONITOR HEAD 1P60, ELECTRONIC CONTROL UNIT 1P40; INPUT VOLTAGE 24 VDC, 24 VAC; POWER CONSUMPTION APPROX 20 TO 50 MA
III SUPPLEMENTARY FEATURES FUNCTIONAL DESCRIPTION DESIGNED TO OPERATE WITH AIR INERT GASES; CALIOMETRIC FLOW MONITORING, WHICH AVOIDS THE NEED FOR MOVING PARTS INTO THE STREAM; CONTINUOUSLY ADJUSTABLE BY MEANS OF A POTENTIOMETER; CORRECT FLOW STATUS IS CLEARLY INDICATED BY A LIGHTED GREEN LIGHT EMITTING DIODE, LED; CONTROLLING AGENCY NOMENCLATURE MINIATURE FLOW MONITOR

Restrictions/Controls & Freight Information | NSN 5930-01-519-4003

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information