Product Details | FLOW SWITCH

5930-01-528-2232 A switch which is specifically designed to operate by the influence of a gaseous, liquid, or solid media velocity on its actuator.

Part Alternates: SPDT 024-A3-F1C-0B0, SPDT024A3F1C0B0, 5930-01-528-2232, 01-528-2232, 5930015282232, 015282232

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 07 MAR 2005 01-528-2232

Drawings & Photos | NSN 5930-01-528-2232


Cross Reference | NSN 5930-01-528-2232

Part Number Cage Code Manufacturer
SPDT 024-A3-F1C-0B0 99899 L-3 COMMUNICATIONS CORPORATION DBA NARDA MICROWAVE EAST

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-528-2232

Technical Data | NSN 5930-01-528-2232

Characteristic Specifications
STYLE DESIGNATOR 28 RECTANGULAR
OVERALL LENGTH 3.500 INCHES NOMINAL
OVERALL HEIGHT 1.000 INCHES NOMINAL
OVERALL WIDTH 1.000 INCHES NOMINAL
BODY LENGTH 2.300 INCHES NOMINAL
NONPILE-UP CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY ACTUATION POINT NOT ADJUSTABLE
CONTACT VOLTAGE RATING IN VOLTS 24.0 DC AT SEA LEVEL SINGLE VOLTAGE
FREQUENCY IN HERTZ 1000000000.0 SINGLE VOLTAGE
CONTACT LOAD CURRENT RATING 180.0 MILLIAMPERES INDUCTIVE LOAD SINGLE VOLTAGE
OPERATING TEMP RATING -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
MEDIA FOR WHICH DESIGNED GAS OR LIQUID
TERMINAL TYPE SOLDER STUD
MOUNTING METHOD UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER 0.209 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5930-01-528-2232

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information