Product Details | TOGGLE SWITCH

5930-01-533-3390 A switch which is externally actuated by a lever and whose contacts open and close with an instantaneous (snap) action; includes items having one or more momentary positions. Includes switches (snap action) which use mercury to bridge contacts, and assemblages of complete switches (snap action) having common actuators. Excludes SWITCH, LEVER; SWITCH, ROTARY; SWITCH, KNIFE; SWITCH, SENSITIVE; and SWITCH, BOX.

Part Alternates: 8500K9 SPST, 8500K9SPST, 5930-01-533-3390, 01-533-3390, 5930015333390, 015333390

Electrical and Electronic Equipment Components | Switches

Supply Group (FSG) NSN Assign. NIIN
59 12-SEP-05 01-533-3390

Drawings & Photos | NSN 5930-01-533-3390


Cross Reference | NSN 5930-01-533-3390

Part Number Cage Code Manufacturer
45A0099 52025 SIEMENS ENERGY & AUTOMATION, INC. DIV SIEMENS ENERGY & AUTOMATION DBA
608915-03 98076 BFM TRANSPORT DYNAMICS CORP
8500K9 81640 EATON CORPORATION DBA FLUID POWER DIV
MS24523-22 96906 MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5930-01-533-3390

Technical Data | NSN 5930-01-533-3390

Characteristic Specifications
MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 10.000 AMPERES INDUCTIVE AC AND 15.000 AMPERES RESISTIVE DC
BODY STYLE 5P BUSHING MOUNT
BODY LENGTH 1.270 INCHES MAXIMUM
BODY WIDTH 1.180 INCHES MAXIMUM

Restrictions/Controls & Freight Information | NSN 5930-01-533-3390

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information