NSN 5940-00-259-5743 M32208AHTC1, M3220-8AHTC1, HL152
Product Details | STUD TERMINAL
5940-00-259-5743 A terminal, generally postlike, having an axial portion of its body designed for projecting through or into a panel, or the like, for mounting. Requires the use of tool(s) for attachment of wire. The conductor connection may be insulated from the mounting. Excludes TERMINAL, FEEDTHRU. See also TERMINAL, QUICK DISCONNECT and TERMINAL SET, QUICK DISCONNECT.
Part Alternates: M32208AHTC1, M3220-8AHTC1, HL152, BMT12MY2, BMT-12MY2, DL132208AHTCI, DL1-3220-8A-HT-CI, DL134498DGP27CI, DL1-3449-8D-GP27-CI, G40P50081, G40P5008-1, BT12, 306-0234-00, 3060234000, 306-0234-000, 54B71741, 54B7174-1, 103A4, 105A, 1373-2-11.2BRN, 13732112BRN, 1JA2379H20, 23082091, 2308-209-1, 2A1A1, 2A1E1, 5940-00-259-5743, 00-259-5743, 5940002595743, 002595743, 306023400
Electrical and Electronic Equipment Components | Lugs, Terminals, and Terminal Strips
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 01 JAN 1963 | 00-259-5743 | 00887 ( TERMINAL, STUD ) |
Demand History | NSN 5940-00-259-5743
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 5940-00-259-5743 | 2025-06-168 | 2 | United States |
| 2A1A1 | 2017-12-342 | 15 | us |
| 5940-00-259-5743 | 2017-04-108 | 1 | DIBBS-RFPs |
| 2A1E1 | 2014-06-162 | 6 | US |
Cross Reference | NSN 5940-00-259-5743
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 103A4 | 92825 | WHITSO INC |
| 105A | 92825 | WHITSO INC |
| 1373-2-11.2BRN | 05791 | LYN-TRON INC |
| 1JA2379H20 | 79500 | WESTINGHOUSE ELECTRIC CORP |
| 1JA2379H20 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN SYSTEMS |
| 2308-209-1 | 17117 | ELECTRONIC MOLDING CORP |
| 2A1A1 | 92825 | WHITSO INC |
| 2A1E1 | 92825 | WHITSO INC |
| 306-0234-00 | 13499 | ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS |
| 306-0234-00 | 55631 | SCOMILL INC |
| 306-0234-00 | 94033 | CARDWELL CONDENSER CORP LAPOINTE-ADMIRAL DIV |
| 306-0234-000 | 13499 | ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS |
| 54B7174-1 | 79500 | WESTINGHOUSE ELECTRIC CORP |
| 54B7174-1 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN SYSTEMS |
| BMT-12MY2 | 91663 | ARMEL ELECTRONICS INC |
| BT12 | 85901 | TYCO ELECTRONICS ELCON POWER CONNECTOR PRODUCTS GROUP |
| BT12 | 91663 | ARMEL ELECTRONICS INC |
| DL1-3220-8A-HT-CI | 27494 | STAFFALL INC. |
| DL1-3449-8D-GP27-CI | 27494 | STAFFALL INC. |
| G40P5008-1 | 94033 | CARDWELL CONDENSER CORP LAPOINTE-ADMIRAL DIV |
| HL152 | 57057 | NAVCOM DEFENSE ELECTRONICS, INC. |
| M3220-8AHTC1 | 27494 | STAFFALL INC. |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5940-00-259-5743
Technical Data | NSN 5940-00-259-5743
| Characteristic | Specifications |
|---|---|
| BASIC SHAPE STYLE | A13 COMPRESSION |
| WIDTH ACROSS FLATS | 0.250 INCHES |
| OVERALL HEIGHT | 0.625 INCHES |
| MAXIMUM HEIGHT ABOVE MOUNTING SURFACE | 0.531 INCHES |
| CONDUCTOR ACCOMMODATION TYPE | BIFURCATED U-FORK SINGLE END |
| SLOT WIDTH | 0.100 INCHES SINGLE END |
| SLOT DEPTH | 0.215 INCHES SINGLE END |
| LARGEST WIDTH | 0.250 INCHES SINGLE END |
| MOUNTING METHOD STYLE | D28 TAPPED HOLE |
| THREAD LENGTH | 0.156 INCHES |
| MOUNTING THREAD SERIES | UNC |
| MOUNTING THREAD DIAMETER | 0.112 INCHES |
| ELECTRICAL INSULATION FEATURE | STANDOFF INSULATION |
| IDENTIFICATION CODE COLOR | BROWN |
| MATERIAL | COPPER ALLOY CONDUCTOR ACCOMMODATION PLASTIC DIALLYL PHTHALATE INSULATION COPPER ALLOY MOUNTING FACILITY |
| SPECIAL FEATURES | MOUNTING BASE CADMIUM PLATED; INSULATION GLASS FILLED DIALLYL PHTHALATE; TEMPERATURE RANGE: -55 DEGREES C TO +125 DEGREES C |
| III PRECIOUS MATERIAL | GOLD AND SILVER |
| III PRECIOUS MATERIAL AND LOCATION | TERMINAL INSERT GOLD AND TERMINAL INSERT SILVER |
| III END ITEM IDENTIFICATION | C-135 AIRCRAFT; AIRCRAFT, STRATOLIFTER C-135 |
Restrictions/Controls & Freight Information | NSN 5940-00-259-5743
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | C | Item contains two or more precious metals |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061680 | ELEC WIRING PLUGS ETC |
| Less than car load rating | ||
| Less than truck load rating | W | Rating Variable |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | XX | |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5940-00-259-5743
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
| Combat Essentiality Code | 1 | Combat Essential End Item. End item equipments whose availability in a combat ready condition is essential for execution of the combat and training missions of the command. |
| Materiel Management Code | G | General Property MaterielDefense Supply Center Richmond (DSCR) |
| Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DM | U.S. Marine Corps |
| Service Organization | M | U.S. Marine Corps |
| Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
H EA : Each |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
H EA : Each |