Product Details | ELECTROMAGNETIC RELAY

5945-00-107-2673 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: HC1S23, SMC503316, RJ1A26N1097, RJ1A-26N1097, RJ1A26N323, RJ1A26S, 247ASC1666002, 247AS-C1666-002, 4100346000, 410-0346-000, 5945-00-107-2673, 00-107-2673, 5945001072673, 001072673

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 24 JUL 1968 00-107-2673

Demand History | NSN 5945-00-107-2673

Part Number Request Date QTY Origin
5945-00-107-2673 2018-06-178 4 US
5945-00-107-2673 2017-04-101 3 US
5945-00-107-2673 2009-12-347 5 Pakistan

Cross Reference | NSN 5945-00-107-2673

Part Number Cage Code Manufacturer
247AS-C1666-002 30003 NAVAL AIR SYSTEMS COMMAND
410-0346-000 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
410-0346-000 95105 ROCKWELL COLLINS, INC. DIV GOVERNMENT SYSTEMS - DALLAS
HC1S23 18741 TYCO ELECTRONICS CORPORATION DBA KILOVAC
RJ1A-26N1097 23905 L-3 COMMUNICATIONS WESTWOOD CORPORATION
RJ1A26N323 73905 JENNINGS TECHNOLOGY COMPANY LLC DBA JENNINGS
RJ1A26N323 C4751 EPCOS AG
RJ1A26N323 D1180 EPCOS AG ABT. PR ROE K PM
RJ1A26S 73905 JENNINGS TECHNOLOGY COMPANY LLC DBA JENNINGS
RJ1A26S C4751 EPCOS AG
RJ1A26S D1180 EPCOS AG ABT. PR ROE K PM
SMC503316 80063 US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-00-107-2673

Technical Data | NSN 5945-00-107-2673

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 2500.0 DC
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 335.0 OHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
TERMINAL TYPE AND QUANTITY 5 PIN ALL FUNCTIONS
DUTY TYPE CONTINUOUS
OVERALL LENGTH 1.560 INCHES NOMINAL
OVERALL DIAMETER 0.940 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING SINGLE MOUNTING FACILITY
THREAD SERIES DESIGNATOR UNS SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE 0.562 INCHES SINGLE MOUNTING FACILITY
THREAD CLASS 2A SINGLE MOUNTING FACILITY
THREAD QUANTITY PER INCH 32 SINGLE MOUNTING FACILITY
THREAD LENGTH 0.688 INCHES NOMINAL SINGLE MOUNTING FACILITY

Restrictions/Controls & Freight Information | NSN 5945-00-107-2673

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-00-107-2673

Category Code Description
Cognizance Codes9NNavy-owned stocks of defense electronic material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9EDefense Supply Center Columbus
Columbus, OH 43218
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each