Product Details | ELECTROMAGNETIC RELAY

5945-00-192-6269 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: 150GB5G1A600, 50GB5N1A700, H996, 5945-00-192-6269, 00-192-6269, 5945001926269, 001926269

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 11 MAR 1970 00-192-6269

Cross Reference | NSN 5945-00-192-6269

Part Number Cage Code Manufacturer
150GB5G1A600 98926 BOEING COMMERCIAL AIRPLANE CO BOEING CO PORTLAND
50GB5N1A700 98927 ELECTRONIC SPECIALTY CORP RELAY DIV
50GB5N1A700 C7407 IV-ELECTRONIC KLAUS VESPERMANN KG
H996 98927 ELECTRONIC SPECIALTY CORP RELAY DIV
H996 C7407 IV-ELECTRONIC KLAUS VESPERMANN KG

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-00-192-6269

Technical Data | NSN 5945-00-192-6269

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES DC RESISTIVE LOAD
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 600.0 OHMS NOMINAL SINGLE WINDING
TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION HERMETIC
OVERALL LENGTH 1.320 INCHES NOMINAL
OVERALL WIDTH 1.580 INCHES NOMINAL
OVERALL HEIGHT 0.400 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 2 SLOTTED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.070 INCHES NOMINAL SINGLE MOUNTING FACILITY
MOUNTING SLOT WIDTH 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY

Restrictions/Controls & Freight Information | NSN 5945-00-192-6269

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable