NSN 5945-00-226-0131 2097302, 3036224509, 30-3622-4509
Product Details | METER MOVEMENT RELAY
5945-00-226-0131 A relay which operates by means of a D'Arsonval or similar meter type actuation.
Part Alternates: 2097302, 3036224509, 30-3622-4509, 5945-00-226-0131, 00-226-0131, 5945002260131, 002260131
Electrical and Electronic Equipment Components | Relays and Solenoids
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 01 JAN 1961 | 00-226-0131 | 03884 ( RELAY, METER MOVEMENT ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5945-00-226-0131
Related Products | NSN 5945-00-226-0131
Technical Data | NSN 5945-00-226-0131
| Characteristic | Specifications |
|---|---|
| MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| MAIN CONTACT CURRENT TYPE | DC |
| MAIN CONTACT CURRENT RATING | 0.006 AMPERES NOMINAL |
| VOLTAGE RATING | 60.0 VOLTS NOMINAL |
| METER MOVEMENT CURRENT TYPE | DC |
| METER MOVEMENT VOLTAGE IN VOLTS | 0.100 NOMINAL |
| METER MOVEMENT CURRENT RANGE | 0.0 TO 100.0 MICROAMPERES |
| SCALE MEASUREMENT RANGE | -2.5 TO 2.5 |
| TERMINAL QUANTITY | 5 |
| TERMINAL TYPE | THREADED STUD |
| METER MOUNTING TYPE | FLUSH |
| METER DEPTH BEHIND MOUNTING FLANGE | 2.015 INCHES NOMINAL |
| MOUNTING FLANGE DIAMETER | 3.000 INCHES NOMINAL |
| METER BODY DIAMETER | 2.750 INCHES NOMINAL |
| CASE MATERIAL | PLASTIC |
| CONTACT CLOSING CONDITION | INCREASE VALUE |
| RESET FACILITY FEATURE | PROVIDED |
| LOCK IN DEVICE TYPE | COIL |
| RELEASE METHOD | DEENERGIZE LOCK-IN COIL |
| MOUNTING CONFIGURATION | FOUR 0.112 IN. DIA MTG HOLES ON 2.250 IN. MTG CENTERS |
| SPECIAL FEATURES | 135 CPS ERROR --FS EQUALS 100 UADC MARKED ON METER FACE |
| III END ITEM IDENTIFICATION | TYPE NO. RTC-2 |
| MANUFACTURERS CODE | 28527 |
| DESIGN CONTROL REFERENCE | 2097302 |
Restrictions/Controls & Freight Information | NSN 5945-00-226-0131
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||