NSN 5945-00-479-6977 MKS2A6, MKS2A-6, GHA2C6VA
Product Details | ELECTROMAGNETIC RELAY
5945-00-479-6977 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.
Part Alternates: MKS2A6, MKS2A-6, GHA2C6VA, KA11AY6, KA11AY-6, KA11AY6V, 04900038, 0490-0038, 04900039, 0490-0039, 250AX6, 250AX-6, 5017535, 5017-535, 5945-00-479-6977, 00-479-6977, 5945004796977, 004796977
Electrical and Electronic Equipment Components | Relays and Solenoids
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 00-479-6977 | 32512 ( RELAY, ELECTROMAGNETIC ) |
Cross Reference | NSN 5945-00-479-6977
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 0490-0038 | 28480 | HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP |
| 0490-0039 | 1LQK8 | KEYSIGHT TECHNOLOGIES, INC. |
| 0490-0039 | 28480 | HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP |
| 250AX-6 | 94696 | SE RELAYS LLC MAGNECRAFT DIV SE RELAYS LLC MAGNECRAFT |
| 5017-535 | 05869 | RAYTHEON COMPANY DBA RAYTHEON |
| GHA2C6VA | 94696 | SE RELAYS LLC MAGNECRAFT DIV SE RELAYS LLC MAGNECRAFT |
| K210K4105 | 82187 | NATIONAL WEATHER SERVICE DBA NATIONAL WEATHER SERVICE OHD1 |
| KA11AG6V | 77342 | TYCO ELECTRONICS CORPORATION |
| KA11AY-6 | 77342 | TYCO ELECTRONICS CORPORATION |
| KA11AY6V | 77342 | TYCO ELECTRONICS CORPORATION |
| MKS02A-6 | 07065 | G GENERAL ELECTRO-COMPONENTS INC |
| MKS2A-6 | 07065 | G GENERAL ELECTRO-COMPONENTS INC |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5945-00-479-6977
Related Products | NSN 5945-00-479-6977
Technical Data | NSN 5945-00-479-6977
| Characteristic | Specifications |
|---|---|
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 26.5 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 4.0 OHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 6.00 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| FREQUENCY IN HERTZ | 60.0 NOMINAL |
| TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| OVERALL LENGTH | 1.730 INCHES NOMINAL |
| OVERALL WIDTH | 1.180 INCHES NOMINAL |
| OVERALL HEIGHT | 1.100 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED HOLE SINGLE MOUNTING FACILITY |
| THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
| NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
| THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
| THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
Restrictions/Controls & Freight Information | NSN 5945-00-479-6977
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||