NSN 5945-00-728-2155 G370054S1, 2830STRS, 28-30STRS
Product Details | THERMAL RELAY
5945-00-728-2155 A relay switch which is actuated by the effect of internal heat generated by the current in its energizing circuit. For items actuated by ambient, rather than internal temperature changes, see SWITCH, THERMOSTATIC.
Part Alternates: G370054S1, 2830STRS, 28-30STRS, 5945-00-728-2155, 00-728-2155, 5945007282155, 007282155
Electrical and Electronic Equipment Components | Relays and Solenoids
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 01 JAN 1961 | 00-728-2155 | 03883 ( RELAY, THERMAL ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5945-00-728-2155
Related Products | NSN 5945-00-728-2155
Technical Data | NSN 5945-00-728-2155
| Characteristic | Specifications |
|---|---|
| CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
| CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
| CONTACT MAXIMUM CURRENT RATING IN AMPS | 2.0 DC |
| HEATER VOLTAGE RATING IN VOLTS | 28.0 |
| HEATER POWER RATING IN WATTS | 10.0 |
| TERMINAL TYPE AND QUANTITY | 5 PIN |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD |
| OVERALL LENGTH | 1.484 INCHES NOMINAL |
| OVERALL WIDTH | 1.234 INCHES NOMINAL |
| OVERALL HEIGHT | 2.125 INCHES NOMINAL |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| SPECIAL FEATURES | THREE NO. 6-32 THD STUDS,0.375 IN. LONG ON AN ISOSCELES TRIANGLE W/BASE 0.750 IN. AND AN APEX OF 1.125 IN. |
| SPECIFICATION/STANDARD DATA | 24930-G370054S1 MANUFACTURERS SOURCE CONTROL |
| MANUFACTURERS CODE | 24930 |
| MFR SOURCE CONTROLLING REFERENCE | G370054S1 |
Restrictions/Controls & Freight Information | NSN 5945-00-728-2155
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061300 | CIRCUIT BREAKER/SWITCH NOI |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | XX | |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5945-00-728-2155
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
| Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
| Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
| Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DM | U.S. Marine Corps |
| Service Organization | M | U.S. Marine Corps |
| Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |