Product Details | ELECTROMAGNETIC RELAY

5945-00-838-4819 A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.

Part Alternates: DJ26D1J6A, 72C828001, 72C828-001, 1CR65, 5945-00-838-4819, 00-838-4819, 5945008384819, 008384819

Electrical and Electronic Equipment Components | Relays and Solenoids

Supply Group (FSG) NSN Assign. NIIN
59 15 SEP 1967 00-838-4819

Cross Reference | NSN 5945-00-838-4819

Part Number Cage Code Manufacturer
1CR65 99699 DRI RELAYS INC. DBA FOREIGN PARENT IS FINANCIERE DE
72C828-001 04660 AIL SYSTEMS INC SUB OF EATON CORP
DJ26D1J6A 99699 DRI RELAYS INC. DBA FOREIGN PARENT IS FINANCIERE DE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5945-00-838-4819

Technical Data | NSN 5945-00-838-4819

Characteristic Specifications
NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 13.5 DC
COIL QUANTITY 1
WINDING QUANTITY 1
WINDING DC RESISTANCE RATING 830.0 OHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 13.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
DUTY TYPE CONTINUOUS
ENVIRONMENTAL PROTECTION HERMETIC
OVERALL LENGTH 1.330 INCHES MAXIMUM
OVERALL WIDTH 0.597 INCHES MAXIMUM
OVERALL HEIGHT 0.455 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.062 INCHES NOMINAL SINGLE MOUNTING FACILITY
UNTHREADED MOUNTING HOLE DIAMETER 0.120 INCHES NOMINAL SINGLE MOUNTING FACILITY
MANUFACTURERS CODE 04660
MFR SOURCE CONTROLLING REFERENCE 72C828-001

Restrictions/Controls & Freight Information | NSN 5945-00-838-4819

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5945-00-838-4819

Category Code Description
Cognizance Codes9NNavy-owned stocks of defense electronic material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9EDefense Supply Center Columbus
Columbus, OH 43218
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative